科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Journal of the American Heart Association2025-10-23· Medicine

Leadless Versus Transvenous Single‐Chamber Ventricular Pacemakers: Real‐World Evidence From Aveir VR Coverage With Evidence Development Study

James E. Ip, Peter A. Brady, Anne M. Kroman, Blandine Mondésert, Leonard I. Ganz, Jennifer Joseph, Deepti Bettampadi, Yajing Hu, Yelena Nabutovsky, Rahul N. Doshi

原始摘要(英文原文)· Original abstract
Background Aveir VR, a helix‐fixation leadless pacemaker (LP), was US Food and Drug Administration (FDA)‐approved in 2022. The performance of this novel LP has not been evaluated against transvenous single chamber ventricular pacemakers (TV‐VVI) in a real‐world setting. This observational coverage with evidence development study of Aveir VR implants (Aveir coverage with evidence development) evaluates complications and outcomes among Medicare beneficiaries implanted with Aveir VR immediately after FDA approval compared with those implanted with TV‐VVI. Methods Medicare fee‐for‐service and Abbott device registration data were used to identify de novo Aveir VR LP (implanted 6/2022–6/2024) or TV‐VVI (all manufacturers, implanted 1/2021–6/2024). Outcomes evaluated included 30‐day and 12‐month complications, reinterventions, and mortality rates, adjusted for demographics, comorbidities, and hospital encounter characteristics. Results Among 2425 Aveir VR LP and 21 335 TV‐VVI patients included in this analysis, Aveir VR patients had significantly fewer acute device‐related complications (1.4% versus 2.8%, P =0.002). Overall acute complications were similar between Aveir VR (6.5%) and TV‐VVI (6.8%), P =0.69. Cardiac effusion/perforation rates were also similar between Aveir VR (0.4%) and TV‐VVI (0.3%), P =0.45. Aveir VR had a 30% lower overall 12‐month complication rate compared with TV‐VVI (4.1% versus 5.7%, P =0.02), including a 47% lower device‐related complication rate (2.8% versus 5.2%, P =0.0002). There were 61% fewer 12‐month reinterventions with Aveir VR compared with TV‐VVI (1.2% versus 3.2%, P <0.0001). Finally, Aveir maintained a comparable 30‐day mortality but a lower 12‐month mortality rate (17.0% versus 18.2%, P =0.02). Conclusions This real‐world evidence study, conducted immediately after commercialization of Aveir VR, demonstrates that safety of helix‐fixation LPs is better than traditional TV‐VVI pacemakers.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Leadless Versus Transvenous Single‐Chamber Ventricular Pacemakers: Real‐World Evidence From Aveir VR Coverage With Evidence Development Study — 科研速览 Science Skim