Circulation. Arrhythmia and electrophysiology

Cardiovascular Outcomes Following Smartwatch Irregular Rhythm Notification: Findings From the Apple Heart Study.

Eduardo Perez-Guerrero, Shyon Parsa, Diona Gjermeni, Maria Sakalaki, Kevin Yu, Haley Hedlin, Manisha Desai, Pouria Alipour,

Department of Medicine (E.P.-G., S.P.), Stanford University School of Medicine, CA. · Division of Cardiovascular Medicine, Department of Medicine (D.G., M.P.T., K.W.M., M.V.P.), Stanford University School of Medicine, CA.

Key points

From the paper's conclusion
  • Receipt of a smartwatch IRN was associated with higher odds of subsequent self-reported cardiovascular events beyond atrial fibrillation. These findings suggest that IRNs may identify individuals at elevated short-term cardiovascular risk.

Abstract

BACKGROUND: Smartwatch irregular rhythm notifications (IRNs) can identify atrial fibrillation. IRNs' association with broader cardiovascular outcomes is unclear. We evaluated whether receipt of an IRN in the AHS (Apple Heart Study) was associated with subsequent self-reported cardiovascular events. METHODS: We performed a post hoc analysis of the AHS, a prospective trial in the United States. Participants were enrolled via an iPhone app from 2017 to 2018; those who completed the end-of-study survey were included. The exposure was IRN receipt. Outcomes were self-reported new heart failure, myocardial infarction, stroke/transient ischemic attack, pulmonary embolism, and a composite of these events (major adverse cardiovascular events). Multivariable-adjusted logistic regression models included age, sex, heart failure, hypertension, diabetes, prior stroke/transient ischemic attack/systemic embolism, and vascular disease. RESULTS: Among 293 944 participants who completed follow-up, 929 (0.32% [95% CI, 0.30%-0.34%]) received an IRN. Participants with an IRN were older, more often male, and had a greater burden of cardiovascular risk factors. At the end-of-study survey, completed 5 to 14 months after enrollment, IRN receipt was associated with higher adjusted odds of self-reported heart failure (odds ratio, 5.43 [95% CI, 3.09-9.57]), stroke/transient ischemic attack (odds ratio, 3.51 [1.91-6.45]), pulmonary embolism (odds ratio, 4.43 [1.92-10.20]), and major adverse cardiovascular events (odds ratio, 4.01 [2.80-5.73]). Among participants with an IRN but without atrial fibrillation, IRN receipt remained associated with statistically significantly higher adjusted odds of self-reported heart failure and major adverse cardiovascular events. CONCLUSIONS: Receipt of a smartwatch IRN was associated with higher odds of subsequent self-reported cardiovascular events beyond atrial fibrillation. These findings suggest that IRNs may identify individuals at elevated short-term cardiovascular risk.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers