American heart journal

Study protocol for The Heart Watch Study - Prognostic performance of smartwatch 12-lead ECG with advanced ECG analysis in consumer self-screening for cardiovascular disease.

Zaidon S Al-Falahi, Todd T Schlegel, Vivian Lee, Clara K Chow, Rebecca Kozor, Thomas Lindow, Martin Ugander

Kolling Institute, Royal North Shore Hospital, and University of Sydney, Sydney, Australia. · Department of Clinical Physiology, Karolinska University Hospital, and Karolinska Institutet, Stockholm, Sweden; Nicollier-Schlegel SARL, Trélex, Switzerland.

Observational · n=30,000

Key points

From the paper's conclusion
  • This study evaluates the feasibility of performing a fully diagnostic standard 12-lead SWECG using only a smartwatch and a smartphone application, and addresses the prognostic value of A-ECG machine-learning based analysis in consumer self-screening in a large, diverse and apparently healthy population.

Abstract

BACKGROUND: It is now possible to acquire a fully diagnostic standard 12-lead electrocardiography (ECG) using a smartwatch, a smartphone app, and no additional hardware. This study aims to evaluate the predictive performance of advanced ECG (A-ECG) analysis applied to a smartwatch 12-lead ECG (SWECG) acquired using an Apple Watch in identifying cardiovascular risks among asymptomatic adults performing consumer self-screening in the general population. METHODS AND DESIGN: The Heart Watch Study is a prospective, Australia-wide observational cohort study. The study will recruit 30,000 participants aged 20-79 years without prior known cardiovascular disease. Participants will enrol and consent electronically, and download a dedicated study iPhone app that enables a directed 12-lead SWECG acquisition using an Apple Watch. The recordings will undergo both conventional and A-ECG analysis. Follow-up will be performed through linkage with administrative health datasets in Australia, including hospital visits and mortality. The primary combined endpoint is all-cause mortality, hospitalization for cardiovascular causes, and incident cardiovascular disease (arrythmia, ischemic heart disease, heart failure) as predicted by existing A-ECG analyses. CONCLUSION: This study evaluates the feasibility of performing a fully diagnostic standard 12-lead SWECG using only a smartwatch and a smartphone application, and addresses the prognostic value of A-ECG machine-learning based analysis in consumer self-screening in a large, diverse and apparently healthy population.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Study protocol for The Heart Watch Study - Prognostic performance of smartwatch 12-lead ECG with advanced ECG analysis in consumer self-screening for cardiovascular disease — Science Skim