Longevity of Non-Rechargeable Implantable Pulse Generators in Deep Brain Stimulation: A Systematic Review.
Mohammad Mofatteh, Keyoumars Ashkan
Key points
From the paper's conclusion- DBS IPG longevity reflects an interaction between stimulation-energy requirements, programming strategy, device architecture, and clinical context. Energy-efficient programming, proactive battery surveillance, and individualized device selection may reduce replacement burden while maintaining effective stimulation. Prospective studies of contemporary IPGs using standardized longevity endpoints are needed to validate and expand these findings.
Abstract
INTRODUCTION: The longevity of non-rechargeable implantable pulse generator (IPG) is an important consideration in deep brain stimulation (DBS), as battery depletion may cause loss of therapeutic benefit, and repeated replacement exposes patients to cumulative surgical morbidity. We aimed to systematically evaluate non-rechargeable DBS IPG longevity, determinants of battery life, comparative device performance, and clinical consequences of battery depletion and replacement. METHODS: PubMed, Scopus, and Web of Science were searched from inception to 2 August 2026. Original human studies reporting non-rechargeable IPG longevity, depletion or replacement, energy consumption, or related clinical outcomes were included; rechargeable IPGs were considered separately. RESULTS: Of 1,476 initial records, 30 studies were included, with reported sample sizes totalling 4,101 observations. Observed non-rechargeable IPG longevity ranged from approximately 2 to >6 years. In a single cohort stratified by indication, longevity was shortest in dystonia (37.0±2.0 months), intermediate in Parkinson's disease (51.5±2.3 months), and longest in essential tremor (71.9±6.7 months), although disease, target, and stimulation requirements were closely interrelated. Higher stimulation-energy demand, including greater amplitude, pulse width, frequency, and total electrical energy delivered (TEED), was consistently associated with shorter longevity. Direct comparisons also demonstrated clinically important differences in longevity between generations of non-rechargeable IPGs, independent of stimulation-energy demand in some cohorts. Major infection occurred after 30 replacements (2.3%), and each previous replacement increased infection odds (OR 1.6). Depletion-associated parkinsonism-hyperpyrexia syndrome resulted in 2 deaths. Overall, 18 studies (60.0%) had a high risk of bias. CONCLUSION: DBS IPG longevity reflects an interaction between stimulation-energy requirements, programming strategy, device architecture, and clinical context. Energy-efficient programming, proactive battery surveillance, and individualized device selection may reduce replacement burden while maintaining effective stimulation. Prospective studies of contemporary IPGs using standardized longevity endpoints are needed to validate and expand these findings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Variability and Drivers of Battery Longevity in Contemporary Implantable Cardioverter-Defibrillator Systems Across Geographic Regions.JACC. Asia · 2026
- Comparative Motor Outcomes and Programming Timelines After Deep Brain Stimulation for Parkinson's Disease With Abbott Infinity™ Versus Medtronic Percept™ Systems.Cureus · 2026
- Time To Stable Programming After Staged vs Simultaneous Bilateral Subthalamic Deep Brain Stimulation Electrode Placement for Parkinson's Disease.World neurosurgery · 2026
- Persistently uneven deep brain stimulation management in Japan: a nationwide claims analysis, 2014-2024medRxiv · 2026
- Deep brain stimulation for arm tremor: one-year blinded follow-up of a randomized trial.Neurological research and practice · 2026