Audiology & neuro-otology

Advanced programming requirements of subjects who undergo simultaneous cochlear implantation and vestibular schwannoma resection.

Maryann Flores Zurrica, Shirin Jivani, Marc-Elie Nader, Franco DeMonte, Shaan Raza, Paul W Gidley, Terry Zwolan

Key points

From the paper's conclusion
  • Patients who received a CI prior to VSR present with various programming challenges and demonstrate variable post-operative speech scores. All 8 patients who received sound with the CI benefited from this procedure, as demonstrated by device use, outcomes, and SSQ-12 responses.

Abstract

INTRODUCTION: Studies examining cochlear implantation (CI) immediately following vestibular schwannoma resection (VSR) demonstrate promising yet often variable improvements in speech understanding. There are no known existing studies that address the programming requirements for this patient population. We report on the advanced CI programming required to provide sound for patients who underwent CI prior to VSR. METHODS: This descriptive study analyzed 12 patients with unilateral vestibular schwannoma who underwent simultaneous CI and VSR. Programming parameters and outcomes were analyzed in 8 of 12 patients who had sound with the CI. Programming parameters included number of active electrodes, pulse width, stimulation rate, maxima, and charge levels required for lower (threshold) and upper stimulation levels (C levels). Patient outcomes included CI sound field thresholds, post-operative scores obtained on CNC Words and AzBio Sentences, datalogging, and scores for the Speech, Spatial and Qualities of Hearing Scale (SSQ) questionnaire. RESULTS: All 8 patients who received sound with their CI required some level of advanced programming, including widening of pulse width, deactivation of electrodes, and reduction of maxima and stimulation rate. Stimulation levels for patients who received a CI prior to VSR were significantly higher than those reported in the literature for non-tumor patients. CONCLUSION: Patients who received a CI prior to VSR present with various programming challenges and demonstrate variable post-operative speech scores. All 8 patients who received sound with the CI benefited from this procedure, as demonstrated by device use, outcomes, and SSQ-12 responses.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers