Thermal‐Hydraulic Sizing and Correlation Uncertainty Assessment of Printed Circuit Heat Exchangers as Steam Generators for Small Modular Reactors
Taeseok Kim
Key points
From the paper's conclusion- These findings indicate that PCHE steam‐generator design cannot be based on a single deterministic model selection alone; instead, designers must work within an uncertainty‐envelope framework that simultaneously bounds thermal length, dryout onset, and hydraulic loss.
Abstract
Printed circuit heat exchangers (PCHEs) are strong candidates for once‐through steam generators in small modular reactors (SMRs), but their sizing is governed by coupled uncertainties in boiling heat transfer, dryout, and two‐phase hydraulic losses. This study examines a PCHE‐type steam generator in which the secondary side enters as subcooled water, traverses the full evaporation interval, and exits as superheated steam, with the channel length sized to achieve a nominal 30‐K superheat target. The reference case uses a 480‐segment one‐dimensional single‐channel model and converges to a required channel length of 1.514 m for a 112.78‐MW one‐module duty. Operating and geometric sweeps show that increasing secondary mass flux raises both duty and pressure‐drop burden, while increasing hydraulic diameter lengthens the exchanger but reduces the cold‐side pressure drop. Model‐form uncertainty produces a still wider design envelope: one‐at‐a‐time closure changes shift the required length from 1.402 to 3.804 m, and the complete 280‐case‐coupled correlation matrix spans 1.401 to 4.086 m. This complete matrix comprises combinations of 4 BHTC models, 10 dryout/CHF models, and 7 pressure‐drop treatments; 271 cases satisfy the strict 0.1‐K outlet‐superheat classification, while nine transition‐sensitive cases are retained within 0.5 K. These findings indicate that PCHE steam‐generator design cannot be based on a single deterministic model selection alone; instead, designers must work within an uncertainty‐envelope framework that simultaneously bounds thermal length, dryout onset, and hydraulic loss. Because the present analysis adopts one‐dimensional assumptions, including uniform channel flow and neglect of axial heat conduction, the reported uncertainty bounds should be regarded as design‐screening results that require future multidimensional validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Approximate Model of Thermoeconomic Optimization for Printed‐Circuit Heat Exchangers in Sodium–Nitrogen Dispatchable Nuclear Power SystemsInternational Journal of Energy Research · 2026
- Screening-level pin-cell neutronic sensitivity of a NuScale Power Module-like SMR fuel lattice to coolant-state perturbations from primary-system degradationKerntechnik · 2026
- Comparative Study of Helical Coil and Bayonet Tube Steam Generator Designs for Molten Salt ReactorsInternational Journal of Energy Research · 2026
- Comparing Heat Extraction from PWR-SMR and HTGR Power Cycles for Hydrogen and Sustainable Aviation Fuel ProductionEnergies · 2026
- Physics-Based Dynamic Modeling of Hydro Generator Cooling System Using Plant Data, Empirical Heat Transfer Correlations and Reduced Parameter EstimationDynamics · 2026
- A High-Pressure Drum-Evaporators in Combined Cycle Power Plants Hybrid Thermodynamic Modelling and Calibration Framework for simulation of cyber-physical threatsJournal of Physics: Conference Series · 2026