Field‐Based Characterization of Stay Cables: Traffic‐Induced Fatigue Demand and Wind‐Vibration Susceptibility
Miguel Anaya-Díaz, Saúl Enrique Crespo-Sánchez, Francisco Javier Carrión-Viramontes, Juan Antonio Quintana-Rodríguez, Andrés Antonio Torres-Acosta
Key points
From the paper's conclusion- Overall, the field measurements provide a direct characterization of stay‐cable mechanical properties and support a screening‐level evaluation of traffic‐induced fatigue demand and wind‐vibration susceptibility.
Abstract
Stay cables are critical components of cable‐stayed bridges and are subjected to repeated stress fluctuations induced by traffic and wind, which may contribute to fatigue damage and vibration‐related deterioration. This study presents a field‐based experimental investigation of two stay cables of the Ing. Antonio Dovalí Jaime Bridge using simultaneous strain and acceleration measurements obtained during a controlled static load test and under normal operating conditions. Natural frequencies and modal damping ratios were identified from acceleration records, while effective flexural stiffness and mass per unit length were estimated using a mechanical cable model. Effective axial stiffness was determined from measured strain increments and corresponding tension‐force variations. The identified properties were then used to estimate live‐load‐induced tension histories during bridge operation. Stress histories in the prestressing strands were processed using rainflow counting to obtain stress‐range distributions and equivalent stress ranges, which were compared with an infinite‐life fatigue threshold. Wind‐vibration susceptibility was additionally assessed using the identified modal damping ratios and a Scruton‐number‐based reference criterion. The results indicate low traffic‐induced fatigue demand during the monitored period, while the low modal damping ratios suggest potential susceptibility to wind‐induced vibrations. Overall, the field measurements provide a direct characterization of stay‐cable mechanical properties and support a screening‐level evaluation of traffic‐induced fatigue demand and wind‐vibration susceptibility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Review of aerodynamic forces, wind-induced vibration characteristics, and control measures for stay cablesAdvances in wind engineering. · 2026
- Mechanism of Fatigue Fracture of Fork-Eye Anchor Heads Induced by Excessive Vibration of Stay Cables in Landscape Cable-Stayed BridgesBuildings · 2026
- Aerodynamic interference between stay cables and suspenders of a long-span hybrid cable-stayed suspension bridgePhysics of Fluids · 2026
- Intelligent Damage Identification of Stay Cables for Long‐Span Cable‐Stayed Bridges by Integration of Physical Modeling and Deep LearningAdvances in Civil Engineering · 2026
- Ambient vibration–based damage detection for sustainable railway infrastructure: a case study of the Vänersborg railway bascule bridgeIOP Conference Series: Earth and Environmental Science · 2026
- Dynamic Sensitivity of Footbridges: Modal Identification, Human-Induced Vibrations, and Emerging Solutions for Sustainable DesignSustainability · 2026