A Super‐Hydrophilic TiO 2 Sensor for In Situ pH Measurement in Soilless Cultivation Substrates With Reduced Error and Fast Response
Zhangyong Yu, Jinchao Ma, Yumei Ye, Jisuo Li, Jinlong Liu, Cheng Chen
Key points
From the paper's conclusion- This work evaluates the in situ pH sensing performance of a super‐hydrophilic pH sensor in soilless cultivation substrates, compared with a conventional glass electrode, and analyzes the underlying mechanisms. pH sensors with the super‐hydrophilic TiO 2 sensitive electrode and the Ag/AgCl reference electrode were prepared and characterized by SEM, AFM, and XPS, along with wettability and pH respon
Abstract
This work evaluates the in situ pH sensing performance of a super‐hydrophilic pH sensor in soilless cultivation substrates, compared with a conventional glass electrode, and analyzes the underlying mechanisms. pH sensors with the super‐hydrophilic TiO 2 sensitive electrode and the Ag/AgCl reference electrode were prepared and characterized by SEM, AFM, and XPS, along with wettability and pH response performance. Soilless substrates of peat, vermiculite, and perlite were prepared with mass water contents (MWCs, θ m ) of 0.2–0.83. The sensors showed maximum deviations from the reference pH (ΔpH) of −0.78 (peat), −0.24 (vermiculite), and −1.14 (perlite) pH units at θ m = 0.2. Compared with the GM, the fabricated sensor achieved comparable deviation levels in water‐saturated substrates, notably exhibiting smaller deviations in substrates with low θ m . The fabricated sensors were substantially faster than the GM across all substrates and moisture conditions, meeting the requirements for rapid in situ pH measurement. The super‐hydrophilicity surface promotes substrate solution spreading, increasing the effective electrode–solution contact area and thereby accelerating electrochemical equilibration at the electrode surface and overcoming low‐moisture limitations. This sensor offers a promising alternative for pH direct measurement (pH‐DM) in soilless cultivation substrates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Darkroom-Free pH Planar Optode via Image Color Correction for Portable Imaging of Extreme Acidity.Analytical chemistry · 2026
- Enabling Rapid pH Equilibration Through Acoustic Microstreaming for Efficient pH Regulation in Microliter-Scale Samples with Screen-Printed Electrodes.Biosensors · 2026
- A Self-Cleanable Microelectromechanical Systems pH Sensor Based on Three-Dimensional Truncated Pyramid Microstructured IrOx/TiO Composite Electrodes.ACS sensors · 2026
- pH-Regulated Sequential Ti-Al Incorporation for Enhanced Water Vapor Adsorption and Mechanical Robustness of Silica-Based Desiccants.Materials (Basel, Switzerland) · 2026
- Low-cost TiO2 passive sensor for detection of glyphosate in airborne particles: laboratory and field evaluation.Environmental technology · 2026
- Laser-Processed All-Paper-Based Wearable and Biodegradable Electrochemical Sensor for Continuous Sweat pH DetectionACS Sustainable Chemistry & Engineering · 2025