Analyzing Color, Surface Roughness, and Microhardness on the Unpolished and Polished Surfaces of Occlusal Splint Materials From Conventional and CAD–CAM Fabrication Methods
Uthai Uma, Thanchanit Lertyingyos, Tharathip Lilitsuvan
Chulalongkorn University
Key points
From the paper's conclusion- Hence, some CAD–CAM materials can perform similarly to conventional splints, highlighting the importance of considering both material and fabrication methods to optimize clinical outcomes.
Abstract
Purpose To evaluate the color, surface roughness, and microhardness of occlusal splints fabricated using conventional and CAD–CAM techniques and to compare the properties of the unpolished and polished surfaces. Materials and Methods A total of 114 specimens (10 × 10 × 5 mm 3 ) were prepared, including one group each of self‐cured (SC) and heat‐cured (HC) occlusal splints, along with two groups each of milled (ML‐A and ML‐B) and 3D‐printed (3D‐A and 3D‐B) splints. One side of each specimen was polished using a sequence of 600‐, 800‐, and 1000‐grit sandpaper, followed by pumice and tallow. The specimens were then tested for color parameters ( L ∗ , a ∗ , b ∗ ), color change (∆ E ), surface roughness (Ra), and Vickers hardness number (VHN). Statistical analysis was performed using SPSS Version 29.0. Results Significant variations were observed in color, surface roughness, and microhardness across the six materials ( p < 0.001). For the unpolished surface, the highest and lowest color values were observed in ML‐B (75.10) and SC (60.55) for L ∗ , SC (0.14) and 3D‐B (−2.19) for a ∗ , and HC (2.47) and SC (−8.92) for b ∗ . There was a significant difference in ∆ E ( p = 0.011), with ML‐A showing the lowest ∆ E . The two with the lowest Ra values were ML‐A (0.085 µm) and ML‐B (0.117 µm). The highest microhardness values were found in ML‐B (19.74 VHN) and HC (18.85 VHN). Polishing significantly affected the properties ( p < 0.05), with significant differences in L ∗ > a ∗ > b ∗ , reduced Ra across all groups, and decreased the VHN in HC and 3D‐B groups. Conclusion Occlusal splint materials fabricated using different techniques had significant differences in color, surface roughness, and microhardness. The ML‐B occlusal splint showed the best overall performance, with high L ∗ , near‐zero b ∗ , moderate a ∗ , low surface roughness, and the highest microhardness. Polishing generally followed the color trend L ∗ > a ∗ > b ∗ , reduced surface roughness in all groups, and decreased microhardness in HC and 3D‐B splints. Hence, some CAD–CAM materials can perform similarly to conventional splints, highlighting the importance of considering both material and fabrication methods to optimize clinical outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of three occlusal splint material systems manufactured by conventional, subtractive, and additive techniques.Clinical oral investigations · 2026
- Artificial Aging and Its Impact on Surface Properties of Conventional and CAD-CAM Occlusal Splint Materials: An In Vitro Comparative Study.International journal of dentistry · 2026
- Effect of Finishing Protocols and Simulated Toothbrushing on the Surface Roughness and Color Stability of Conventionally and Digitally Fabricated Interim Restorative MaterialsCoatings · 2026
- Color Stability and Surface Roughness of Two Restorative Material-Production Systems: Effects of Surface Finishing and Brushing with Two Commercial Toothpastes with Different RDA Classifications.Dentistry journal · 2026
- Biocompatibility of five occlusal splint materials produced by four fabrication methods: an in vitro comparative studyBMC Oral Health · 2026
- Effect of Resin Type, Layer Thickness, and Printing Orientation on the Mechanical and Surface Properties of 3D-Printed Occlusal SplintsPolymers · 2026