A Hybrid PCF‐SPR Sensor for Electrolyte Sensing Using Finite Element Method and Machine Learning
Nayan Roy, Sourov Das, Shahriar Amin, Hasan Sarker
Key points
From the paper's conclusion- Support vector regression (SVR) performed best ( R 2 = 0.999, RMSE = 0.032, and MAE = 0.0206, MAPE = 1.230%), confirming the strong sensing potential of the proposed sensor.
Abstract
This research presents a novel PCF‐SPR sensor with a dual‐sensing mechanism that allows both internal and external sensing in a single fiber. Since the internal and external regions detect two separate analytes independently, the sensor is well suited for hybrid sensing. This is made possible by a gold film that is uniformly coated on the outer surface of the fiber and on the outer wall of the internal analyte channel, and it excites the surface plasmon resonance (SPR) effect. The sensor shows strong performance over a broad refractive index range, covering 1.26–1.34 for internal sensing and 1.33–1.41 for external sensing. All simulations were performed using the finite element method (FEM) in COMSOL Multiphysics 6.1a. The optimized sensor achieves maximum wavelength sensitivities of 10,000 nm/RIU (internal) and 3000 nm/RIU (external) and maximum amplitude sensitivities of −677.56 RIU −1 (internal) and −86.39 RIU −1 (external). The minimum sensor resolutions (SRs) are 1.00 × 10 −5 RIU (internal) and 3.33 × 10 −5 RIU (external), and the figures of merit (FOMs) are 166.62 RIU −1 (internal) and 15.87 RIU −1 (external). To evaluate the hybrid sensing performance, two electrolytes, KCl and CaCl 2 , were used as representative analytes, with wavelength sensitivities of 1937.98 nm/RIU and 8000 nm/RIU, respectively. Finally, machine learning models were applied to predict the confinement loss. Support vector regression (SVR) performed best ( R 2 = 0.999, RMSE = 0.032, and MAE = 0.0206, MAPE = 1.230%), confirming the strong sensing potential of the proposed sensor.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Smart SPR Biosensors: Machine Learning‐Augmented Dual‐Channel PCF TechnologyAdvanced Photonics Research · 2026
- Learning-assisted full-spectrum refractive-index interrogation for a plasmonic photonic crystal fiber sensor modeled by the finite element methodMeasurement Science and Technology · 2026
- Machine learning-driven optimization of monolithic gold plasmonic sensors: Achieving ultrahigh sensitivity with interpretable linear modelsPLoS ONE · 2026
- Simultaneous dual-analyte detection biosensor through a stacking-based ensemble machine learning approach: design and optimizationBiomedical Optics Express · 2026
- Numerical analysis of balanced geometry selection in circular PCF SPR biosensors for cancer and bacterial detectionOptics Continuum · 2026
- Peak‐Aligned Gaussian‐Process‐Regression‐Assisted Plasmonic Refractive Index SensorInternational Journal of Optics · 2026