DFIG Low‐Voltage Ride‐Through in Weak Grids: Rotor Overcurrent, PLL Effects, and Crowbar Boundaries

Abdullah Alassaf, Ibrahim Alsaleh

Key points

From the paper's conclusion
  • The results show that weaker grids and deeper sags increase rotor‐current stress, while higher prefault wind speed reduces crowbar headroom.

Abstract

Doubly‐fed induction generator (DFIG) wind turbines can experience severe rotor overcurrent during low‐voltage ride‐through (LVRT) in weak grids because voltage magnitude and angle disturbances interact with converter and phase‐locked‐loop (PLL) dynamics. Using a 20‐state nonlinear DFIG model and a prescribed short‐circuit‐ratio (SCR)‐dependent point of common coupling (PCC)‐voltage profile, this paper shows that the weak‐grid disturbance separates into two distinct forcing channels: a magnitude channel, into which sag depth, grid strength, and the profile‐current term collapse through a single scalar, and an angle channel, carried by a phase offset that depends on grid strength independently of the retained magnitude. A first‐order dq‐frame relation gives the route by which reference‐frame angle error propagates into rotor current. The decomposition predicts that two operating points with equal retained magnitude but different grid strength must give different rotor‐current peaks, and a magnitude‐matched pair confirms this: at retained voltages of 0.540 and 0.533 pu, a 57% larger PLL‐angle excursion raises the peak from 1.884 to 1.948 pu. Grid strength, sag depth, and prefault wind speed are then examined within a common simulation framework, with protection‐boundary cases checked for time‐step convergence. The results show that weaker grids and deeper sags increase rotor‐current stress, while higher prefault wind speed reduces crowbar headroom. Under the settings studied, a 30% sag at 11 m/s stays below the 2.0 pu crowbar threshold at SCR = 5 (1.884 pu) but exceeds it at SCR = 3 (2.524 pu), and at SCR = 3 the sag‐depth transition lies between 20% and 30%. Consistent case‐study implementation yields matching protection decisions at common operating points, 2.524 against 2.528 pu at the shared point. A Monte Carlo propagation over wind‐speed variability and machine, controller and profile tolerances shows that the transition is probabilistic rather than sharp: the nominally safe SCR = 5 case still activates the crowbar in 18% of samples. Targeted sensitivity tests also show that the prescribed weak‐grid profile term, PLL bandwidth, and rotor‐side‐converter (RSC) current‐controller tuning can shift a near‐boundary case, confirming that network representation and controller dynamics jointly affect protection behavior. Rotor‐speed, electromagnetic‐torque, stator‐current, and DC‐link responses are included to broaden the dynamic assessment. Voltage‐profile recovery and active‐power recovery are reported as separate metrics throughout. The two‐channel structure explains why grid strength cannot be reduced to an equivalent sag depth, and it gives a fully parameterized, reproducible basis for DFIG protection screening in weak grids.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers