Comparison of Sizing Methods to Optimize Device Selection for Percutaneous Closure of Atrial Septal Defects.
Çağdaş Vural, Ali Baykan, Alper Doğan, Yunus Emre Kum, Özge Pamukçu Akay, Kazım Üzüm, Nazmi Narin
Pediatric Cardiology Department Medical Faculty Mustafa Eraslan Children Hospital Erciyes University Melikgazi Kayseri 38030 Turkey erciyes.edu.tr. · Eskişehir City Hospital, 71 Evler Neighborhood Çavdarlar Street Odunpazarı, Eskişehir 26080, Turkey.
Key points
From the paper's conclusion- Combining multiple measurement techniques improves agreement with the operator-selected device size during percutaneous ASD closure. While TTE alone may be sufficient in patients with simple defects and adequate acoustic windows, integrated approaches incorporating TEE and multiaxis measurements showed favorable agreement characteristics, particularly in anatomically heterogeneous defects or resource-limited settings. These findings should be interpreted as reflecting agreement with operator-selected device sizing rather than anatomical sizing accuracy, given the inherent circularity of using implanted device size as a reference standard.
Abstract
BACKGROUND AND AIMS: Accurate sizing of atrial septal defects (ASDs) is crucial for appropriate device selection during percutaneous transcatheter closure. Despite the availability of multiple imaging and sizing techniques, no consensus exists on the optimal method for determining device size. This study aimed to compare preprocedural ASD measurements obtained using different techniques with the final device waist diameter and to identify the measurement method demonstrating the most favorable agreement and reproducibility. METHODS: This retrospective study included 149 pediatric patients (64 males, 85 females) who underwent percutaneous transcatheter ASD closure. Preprocedural defect sizing was performed using transthoracic echocardiography (TTE), balloon sizing, and transesophageal echocardiography (TEE). TEE measurements were obtained in the four-chamber, aortic, and bicaval views. In addition to individual diameters, the arithmetic mean, cube root-derived diameter, and maximal TEE-measured diameter were calculated and compared with the final device waist diameter. The final device waist diameter, measured fluoroscopically after deployment, was used as the reference comparator, reflecting operator-selected device sizing rather than true anatomical defect dimensions. RESULTS: Among TEE-based measurements, both the cube root-derived diameter and the arithmetic mean of TEE measurements demonstrated high reproducibility and favorable agreement with the final device waist diameter, with only marginal numerical differences between the two methods. Bland-Altman analysis supported these findings by showing minimal bias and narrow limits of agreement, whereas TTE and balloon sizing demonstrated lower, though statistically significant, concordance with the final device waist diameter. CONCLUSION: Combining multiple measurement techniques improves agreement with the operator-selected device size during percutaneous ASD closure. While TTE alone may be sufficient in patients with simple defects and adequate acoustic windows, integrated approaches incorporating TEE and multiaxis measurements showed favorable agreement characteristics, particularly in anatomically heterogeneous defects or resource-limited settings. These findings should be interpreted as reflecting agreement with operator-selected device sizing rather than anatomical sizing accuracy, given the inherent circularity of using implanted device size as a reference standard.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Imaging the Adult With Secundum Atrial Septal Defect: A Practical Echocardiographic Approach From Diagnosis to Device Closure.Echocardiography (Mount Kisco, N.Y.) · 2026
- Identifying a Favorable Morphological Profile for Transcatheter Atrial Septal Defect Closure in Patients With Deficient Posteroinferior Rims.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Transcatheter Closure of Secundum Atrial Septal Defects in Children: Procedural Outcomes and Anatomical Findings from a Single-Center Experience Spanning 2014-2024.Children (Basel, Switzerland) · 2026
- Superior Vena Cava Compromise During Transcatheter Atrial Septal Defect Closure: A Lesson in Implantation Geometry.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Three-Dimensional Transthoracic Echocardiography as a Tool for Patient Selection for Percutaneous Atrial Septal Defect Closure.Pediatric cardiology · 2026
- Transcatheter closure of a quadriform atrial septal defect with a custom double-fenestrated occluder: A case report.Fujita medical journal · 2026