Sequential Bilateral Cochlear Implantation via the Transmastoid Labyrinthotomy Approach Using Custom-Made Electrodes in a Pediatric Patient With Common Cavity Deformities: A Case Report.
Ciro Lucio Vigliaroli, Millo Achille Beltrame, Lazzaro Cassano, Francesca Pia Cavalluzzo, Deniis Curatolo, Alessandra Rossato, Michele Cassano, Eleonora M C Trecca
Department of Otorhinolaryngology and Maxillofacial Surgery, Hospital Casa Sollievo della Sofferenza, San Giovanni Rotondo, Foggia, Italy. · Department of Otorhinolaryngology, Santa Maria del Carmine Hospital, Rovereto, Trento, Italy.
Key points
From the paper's conclusion- We report the case of a pediatric patient with bilateral common cavity deformities who underwent sequential bilateral CI using the double posterior transmastoid labyrinthotomy (TML) approach with custom-made electrodes.
Abstract
Inner ear malformations (IEMs) present significant challenges for cochlear implantation (CI), particularly the common cavity deformity, in which the cochlea and vestibule merge into a single space. Surgical and audiological outcomes in such cases depend on accurate electrode placement, nerve integrity, and tailored surgical strategies. We report the case of a pediatric patient with bilateral common cavity deformities who underwent sequential bilateral CI using the double posterior transmastoid labyrinthotomy (TML) approach with custom-made electrodes. The patient, diagnosed with profound bilateral sensorineural hearing loss at 1 year of age, showed bilateral common cavities with identifiable but reduced caliber seventh and eighth cranial nerves on radiological imaging and absent responses on auditory brainstem response testing. Based on preoperative imaging, a custom-made MED-EL FORM19 electrode (Innsbruck, Austria) was selected and adapted to match the patient's anatomy, aiming to optimize placement and reduce intraoperative complications. A staged implantation was performed. Surgery was uneventful, with intraoperative neural response telemetry confirming responses in both ears. At four-year follow-up, aided thresholds were stable in the speech frequency range (right ear: 40-60 dB HL; left ear: 50-65 dB HL). Speech audiometry in quiet demonstrated good detection and recognition, and language development was appropriate for hearing age, with significant improvement from baseline. This case illustrates that double posterior TML with custom-made electrodes is a safe and effective strategy for CI in complex IEMs such as common cavity deformities. The technique offers precise electrode placement, minimizes risks to the facial nerve, and ensures stable fixation. Early bilateral stimulation, active family involvement, multidisciplinary care in specialized centers, and tailored electrode design are critical to achieving favorable long-term outcomes. Multicenter studies are needed to further validate these findings and refine patient selection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transcanal Cochlear Implantation Under Endoscopic Guidance with Canal Closure in a Pediatric Patient with CHARGE Syndrome: A Case Report and Surgical Technique.Acta medica Okayama · 2026
- Evaluation of manual and robot-assisted electrode placement in malformed cochleae using imaging-based patient specific 3D models.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Cochlear implantation via the retrofacial route in a child with a malformed inner ear: A clinical capsule report.European annals of otorhinolaryngology, head and neck diseases · 2026
- Scala Tympani Versus Scala Vestibuli Cochlear Implantation in Incomplete Partition Type III MalformationJournal of Craniofacial Surgery · 2026
- Cochlear Implantation in a Child With Arnold-Chiari Syndrome, Severe Inner Ear Malformations, and Cochlear Nerve Hypoplasia: A Case Report.The American journal of case reports · 2026
- Piezoelectric shaping of radical mastoid cavity and dissection of ossified cochlea prior to cochlear implantation.Journal of surgical case reports · 2026