Evaluation of manual and robot-assisted electrode placement in malformed cochleae using imaging-based patient specific 3D models.
Fiona Anna Molnár, Mária Matuz, Zoltán Tobiás, Zsolt Geretovszky, Zsófia Bere, Haadi Mollabux, Roland Nagy, László Rovó,
Department of Otorhinolaryngology, Head and Neck Surgery, University of Szeged, Szeged, Hungary. drmolnarfiona@gmail.com. · Institute of Clinical Pharmacy, Faculty of Pharmacy, University of Szeged, Szikra Street 8, Szeged, Hungary.
Key points
From the paper's conclusion- In malformed cochleae, insertion completeness was influenced primarily by cochlear morphology and electrode characteristics within the outcome measures assessed. Patient-specific 3D models provide a useful platform for electrode-anatomy compatibility assessment and preoperative planning; however, clinical validation incorporating tonotopic coverage, audiological outcomes, and objective robotic performance metrics is warranted.
Abstract
PURPOSE: Cochlear implantation in congenital inner ear malformations can be technically challenging due to the atypical anatomy which can limit electrode selection, trajectory, and insertion depth. Although high-resolution CT/MRI and planning tools (e.g., OTOPLAN®) support preoperative assessment, severe malformations may require additional validation. We evaluated whether robot-assisted insertion improves insertion performance in malformed cochleae using patient-specific 3D models. METHODS: High-resolution CT and/or MRI from 8 paediatric candidates were used to reconstruct and 3D print 16 cochleae (malformed cochleae plus one anatomically normal control with eighth nerve aplasia, as applicable). Four electrode arrays (MED-EL Medium, MED-EL Compressed, MED-EL Flex24, and Cochlear Straight) were inserted by an expert surgeon (P1), a novice surgeon (P2), and a robotic system (RobOtol®, R1). Outcomes were insertion completeness (complete/incomplete) and ease (easy/hard). Data were analysed using Firth's penalized logistic regression and classification tree analysis. Preoperative prediction by P1 alone versus P1 + OTOPLAN® was compared using standard classification metrics. RESULTS: Electrode type and cochlear anatomy were the primary determinants of insertion outcomes. Electrode arrays with shorter active lengths (MED-EL Compressed) demonstrated higher insertion completeness in anatomically restricted malformed cochleae, whereas Flex24 and Cochlear Straight showed reduced completeness in restrictive hypoplastic cochleae. Operator identity, including robotic assistance, had minimal impact; ease was generally high. OTOPLAN® assisted planning improved prediction performance and reduced false-negative assessments. CONCLUSION: In malformed cochleae, insertion completeness was influenced primarily by cochlear morphology and electrode characteristics within the outcome measures assessed. Patient-specific 3D models provide a useful platform for electrode-anatomy compatibility assessment and preoperative planning; however, clinical validation incorporating tonotopic coverage, audiological outcomes, and objective robotic performance metrics is warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of robotic-assisted and manual cochlear implant electrode array insertions considering cochlear geometric factors.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
- Sequential Bilateral Cochlear Implantation via the Transmastoid Labyrinthotomy Approach Using Custom-Made Electrodes in a Pediatric Patient With Common Cavity Deformities: A Case Report.Case reports in otolaryngology · 2026
- Impact of Robotic-Assisted Electrode Array Insertion on Neural Health and Hearing Outcomes in Cochlear Implant Recipients.Audiology & neuro-otology · 2026
- Cochlear implantation via the retrofacial route in a child with a malformed inner ear: A clinical capsule report.European annals of otorhinolaryngology, head and neck diseases · 2026
- Early Clinical Experience With Robot-Assisted Electrode Insertion in Cochlear Implantation Using the Otoarm-Otodrive System.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2026
- Partial insertion and electrode array migration in 918 lateral wall cochlear implant electrode arrays: dependence on electrode array design and learning curvesFrontiers in Neurology · 2026