Refractory Intraprocedural Ventricular Fibrillation From Left Circumflex Culprit Occlusion Managed With Culprit PCI and Short-Duration Impella Support.
Vineet Madishetty, Alexander Yaylayan, Kevin Schneider, Varun Yelamanchili, Merrill Krolick
Internal Medicine/Cardiology, HCA Healthcare/USF Morsani College of Medicine, GME/HCA Florida Largo Hospital, Largo, Florida, USA.
Key points
From the paper's conclusion- Short-duration Impella support may serve as an individualized bridge during recovery from recurrent arrest and transient circulatory collapse.
Abstract
BACKGROUND: Ventricular fibrillation (VF) is a life-threatening complication of acute coronary syndrome (ACS) and requires rapid identification and correction of reversible ischemic triggers. ST-segment elevation in aVR with diffuse ST depression reflects global subendocardial ischemia but is not specific for left main or proximal left anterior descending disease. CASE SUMMARY: A 62-year-old male with prior coronary stent placement presented with acute chest pain, diaphoresis, nausea, and vomiting. An electrocardiogram demonstrated ST-segment elevation in aVR with ST depressions in V3-V6. Laboratory testing demonstrated severe metabolic acidosis (pH 7.07; bicarbonate 10.3 mEq/L), lactate 3.7 mmol/L, and high-sensitivity troponin rising from 427 to 4991 ng/L within 2 h. During emergent angiography, VF developed after left ventricular catheter manipulation and recurred repeatedly while attempting to cross a heavily calcified 99% proximal left circumflex (LCx) lesion. Over 20-30 min, 11 VF episodes required immediate defibrillation, manual chest compressions, and intravenous amiodarone. VF ceased only after LCx stenting restored TIMI Grade 3 flow. The patient's maximum intraprocedural shock severity met SCAI Stage E criteria because of recurrent cardiac arrest, multiple defibrillations, and severe acidosis. An Impella microaxial flow pump was placed for temporary postresuscitation circulatory support and maintained at P4. A postreperfusion echocardiogram obtained during ongoing support showed an LVEF of approximately 60%. The device was removed within 48 h after hemodynamic recovery. Staged intravascular lithotripsy-assisted PCI of the calcified mid-LAD lesion was performed on Day 4. DISCUSSION: This case demonstrates that refractory ischemia-mediated VF may terminate only after culprit-vessel reperfusion. A preserved LVEF measured after reperfusion during mechanical support does not exclude earlier SCAI Stage E shock. Short-duration Impella support may serve as an individualized bridge during recovery from recurrent arrest and transient circulatory collapse.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Case Report of Short-Coupled Ventricular Fibrillation Unmasked During Post-Infarction Inflammatory Remodeling.Clinical case reports · 2026
- Electrical storm after percutaneous coronary intervention for subacute anterior myocardial infarction with heart failure, treated with multidisciplinary therapy.BMJ case reports · 2026
- Mechanical Circulatory Support with iVAC2L During High-Risk Percutaneous Coronary Intervention: A Case Report.Journal of clinical medicine · 2026
- Feasibility and Safety of Strategic Multielectrode Positioning Guided by S3 Protocol for Hemodynamically Unstable Ventricular Tachycardia: The S3-STaMP Project.JACC. Clinical electrophysiology · 2026
- Ventricular Fibrillation During Pulsed Field Ablation With Dual-Energy Focal Catheters in Patients With Cardiac Implantable Electronic Devices.Heart rhythm · 2026
- Occult ventricular fibrillation during on-pump beating coronary artery bypass grafting: A case reportJCA advances. · 2026