Mechanical Circulatory Support with iVAC2L During High-Risk Percutaneous Coronary Intervention: A Case Report.
Gerda Sibirkstyte, Mindaugas Barauskas, Martynas Jurenas, Ramunas Unikas, Marcelo B Bastos, Chrisna de Wet Breukelen
Faculty of Medicine, Medical Academy, Lithuanian University of Health Sciences, 44307 Kaunas, Lithuania. · Department of Interventional Cardiology, Erasmus University Medical Center, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands.
Key points
From the paper's conclusion- Temporary mechanical circulatory support may be considered after individualized Heart Team assessment; however, clinical experience with the pulsatile iVAC2L device remains limited.
Abstract
Background: High-risk percutaneous coronary intervention (HR-PCI) in patients with severe left ventricular (LV) systolic dysfunction and complex coronary artery disease may be complicated by abrupt intraprocedural hemodynamic deterioration. Temporary mechanical circulatory support may be considered after individualized Heart Team assessment; however, clinical experience with the pulsatile iVAC2L device remains limited. Case Presentation: An 84-year-old man presented with inferior ST-segment-elevation myocardial infarction, acute decompensated heart failure, pulmonary edema, and an LV ejection fraction of 10-15%. Coronary angiography (CAG) showed a presumed chronic total occlusion of the right coronary artery (RCA) and critical disease of the left main (LMCA), left anterior descending (LAD), and left circumflex (LCx) arteries. Preparation for coronary artery bypass grafting was initiated, but clinical deterioration prompted PCI. The first attempt was aborted after cardiac arrest during coronary wiring. Following stabilization and repeat Heart Team assessment, iVAC2L-supported HR-PCI was performed. During 60 min of active pump support, five stents were implanted in the LMCA, LAD, and LCx. The patient remained conscious and hemodynamically stable without vasopressors. LV ejection fraction was approximately 20% at discharge after six hospital days, and the patient was transferred to inpatient rehabilitation. Conclusions: In this selected patient, iVAC2L-supported HR-PCI was technically feasible and was associated with maintained intraprocedural hemodynamic stability. A single case cannot establish comparative safety or efficacy; prospective studies are required to define patient selection, procedural protocols, and clinically meaningful outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mechanical circulatory support in high-risk elective PCI: rationale and design of the PROTECT IV trialEuroIntervention · 2025
- Left ventricular functional recovery after complex high-risk indicated percutaneous coronary intervention supported with microaxial flow pumpJournal of Cardiovascular Medicine · 2025
- Radiologic predictors of access-site complications during support with micro-axial flow pump support in infarct-related cardiogenic shock and high-risk percutaneous coronary interventionEuropean Heart Journal · 2026
- CORVAD 4.0-assisted complex left main PCI in high-risk acute coronary syndrome with SCAI stage C cardiogenic shock: A case report.The International journal of artificial organs · 2026
- Ventricular free-wall rupture, ventricular pseudoaneurysm, and papillary muscle rupture complicating acute myocardial infarctionEuropean Journal of Cardio-Thoracic Surgery · 2026
- Role of mechanical circulatory support in mechanical complications of acute myocardial infarction.REC, interventional cardiology · 2026