Circular Loop Ligation for Securing Endobronchial Valve in the Treatment of Bronchial Stump Fistula.
Liping Wang, Jiagan Xu, Zhongliang He, Shunxin Xin, Congbin Peng, Weihua Xu
Department of Pulmonary and Critical Care Medicine, Tongde Hospital of Zhejiang Province, Hangzhou, Zhejiang, China, zjtongde.com. · Cardiothoracic Surgery Department, Tongde Hospital of Zhejiang Province, Hangzhou, Zhejiang, China, zjtongde.com.
Key points
From the paper's conclusion- The circular loop ligation methods for securing the EBV enable effective BSF closure in SVBSF2, especially SVBSF2a cases. This technique enables some BSF patients with abnormal structures at bronchial stumps to successfully perform the EBV occlusion.
Abstract
BACKGROUND: Bronchial stump fistula (BSF), which is located on the bronchial stump following pulmonary resection, represents a distinct subtype of bronchopleural fistula (BPF). Although the endobronchial valve (EBV) has been used to treat BPF, few clinical studies involve BSF occluded by EBV because the abnormal bronchial stump makes EBV implantation challenging. The present research reports novel methods of using a circular loop ligation technique for securing EBV to achieve BSF occlusion and a new classification of BSF that is compatible with these novel methods. METHODS: Based on the length of the bronchial stump, small visible BSF (SVBSF, less than 8 mm) is classified into the following types: SVBSF1 (< 3 mm), SVBSF2 (≥ 3 mm but shorter than a normal bronchus), and SVBSF3 (preserves a complete bronchial structure). SVBSF2 is further classified into SVBSF2a (the stump base remains partially intact) and SVBSF2b (complete destruction of the stump base). This retrospective research involved SVBSF2 patients who underwent EBV fixation with circular loop ligation. Detailed medical records were collected and analyzed to evaluate the efficacy of the novel procedure. RESULTS: A total of 15 patients underwent EBV implantation and fixation. All patients achieved a resolution of air leakage. Postoperative assessment revealed no instances of EBV displacement among VBSF2a patients, with all cases exhibiting significant improvement. CONCLUSIONS: The circular loop ligation methods for securing the EBV enable effective BSF closure in SVBSF2, especially SVBSF2a cases. This technique enables some BSF patients with abnormal structures at bronchial stumps to successfully perform the EBV occlusion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Uniportal thoracoscopic suture fixation of an endobronchial spigot for postoperative bronchial fistula.Respiratory medicine case reports · 2026
- Interventional techniques and strategies for postoperative bronchopleural fistula treatment: a narrative review.Journal of thoracic disease · 2026
- Bronchoscopic biological sealing of a bronchopleural fistula in post-tuberculous lung disease: a case report.Frontiers in medicine · 2026
- Transsternal bronchial closure: a narrative review.Journal of thoracic disease · 2026
- Endobronchial valves for management of persistent air leak in advanced cystic fibrosis: A case report and review of literature.Respiratory medicine case reports · 2026
- Autologous Blood Patch Pleurodesis Without Valve Removal for Persistent Air Leak After Bronchoscopic Lung Volume Reduction: A Case Report.Respirology case reports · 2026