Uniportal thoracoscopic suture fixation of an endobronchial spigot for postoperative bronchial fistula.
Gaku Yamaguchi, Haruka Kanai, Atsushi Morio
International University of Health and Welfare, Ichikawa Hospital Division of Thoracic Surgery, Chiba, Japan. · Thoracic Surgery Department, Noda General Hospital, Chiba, Japan.
Key points
From the paper's conclusion- Thoracoscopic suture fixation of an EWS is a minimally invasive and effective option for stabilizing the device in large postoperative bronchial fistulas where bronchoscopic placement alone is insufficient. This technique may be useful when direct stump closure is difficult due to tissue fragility.
Abstract
BACKGROUND: Postoperative bronchial fistula is a serious complication after lung resection, and when empyema develops, bronchoscopic placement of an Endobronchial Watanabe Spigot (EWS) is often attempted. However, in large postoperative fistulas, the EWS cannot be securely fixed and frequently migrates, rendering it ineffective. No established method exists to stabilize the EWS in such cases. CASE REPORT: A man in his 70s developed a persistent bronchial fistula after left lower lobectomy and lingular resection for metastatic lung cancer. An L-size EWS was placed bronchoscopically, but he developed empyema. Although the infection was controlled with antibiotics, the device repeatedly migrated into the pleural cavity, and the air leak persisted. TREATMENT: Using a single-port thoracoscopic approach, the fistula and the dislodged EWS were directly visualized. Because the bronchial wall was fragile, suturing the bronchial wall alone carried a risk of rupture. The EWS was fixed to the stump by passing sutures through the bronchial wall, the spigot, and the opposite bronchial wall. After a leak test, no residual air leak was detected. RESULTS: The chest drain was removed on postoperative day 3. Bronchoscopy at 6 months confirmed complete closure of the fistula. The patient later died from recurrent colorectal cancer without recurrence of empyema or air leakage. CONCLUSION: Thoracoscopic suture fixation of an EWS is a minimally invasive and effective option for stabilizing the device in large postoperative bronchial fistulas where bronchoscopic placement alone is insufficient. This technique may be useful when direct stump closure is difficult due to tissue fragility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Circular Loop Ligation for Securing Endobronchial Valve in the Treatment of Bronchial Stump Fistula.Canadian respiratory journal · 2026
- Bronchoscopic Localization of a Post-Surgical Persistent Air Leak Facilitating Successful Treatment With a Hybrid Imaging-Guided Percutaneous Sealing of Fistula and Autologous Blood Patch Technique.Respirology case reports · 2026
- Robotic repair of an esophago-left main bronchial fistula using a pedicled autologous pericardial patch and latissimus dorsi muscle flap: a novel technique after chemoradiotherapy for cT4b esophageal cancer.Esophagus : official journal of the Japan Esophageal Society · 2026
- A less invasive alternative to fenestration for selected localized postoperative empyema with persistent air leak: prolonged open drainage using a large-sized cut tube in two patients.General thoracic and cardiovascular surgery cases · 2026
- Interventional techniques and strategies for postoperative bronchopleural fistula treatment: a narrative review.Journal of thoracic disease · 2026
- Transsternal bronchial closure: a narrative review.Journal of thoracic disease · 2026