Advances in Civil Engineering

Performance‐Based Structural Design Framework for Asymmetric Multitower Connected High‐Rise Buildings: Evidence From Four Code‐Exceeding Projects

Zhu Xuping, Lili Zhang, Lou Kai, Ze An, Zhang Yaying, Lianshu Li

Key points

From the paper's conclusion
  • To address this limitation, this paper develops a project‐derived performance‐based design methodology for asymmetric connected high‐rise structures, grounded in four representative code‐exceeding projects that cover three dominant configurations: asymmetric twin‐tower rigid connection, large‐chassis multitower flexible connection, and high‐position three‐tower hybrid connection.

Abstract

Asymmetric multitower connected high‐rise buildings represent a prevalent yet structurally complex typology in modern urban construction, featuring mismatched dynamic characteristics between towers, superposition of multiple irregularities, intricate mechanical behavior of connecting elements, and underdeveloped design criteria for key components. Current design codes primarily provide principle‐level requirements for such structures, leaving a gap in project‐level quantitative design procedures and systematic performance control workflows. To address this limitation, this paper develops a project‐derived performance‐based design methodology for asymmetric connected high‐rise structures, grounded in four representative code‐exceeding projects that cover three dominant configurations: asymmetric twin‐tower rigid connection, large‐chassis multitower flexible connection, and high‐position three‐tower hybrid connection. Four engineering methodologies are synthesized, applied to the four projects, and internally checked: (1) a three‐zone refined shear‐wall layout method based on dynamic response zoning; (2) provisional connection‐system selection thresholds using intertower differences in natural period and lateral stiffness; (3) a shear‐force correction method for inclined columns that excludes the horizontal component of axial force; and (4) a six‐level performance classification system for key components paired with a dual‐model envelope design rule. The framework is evaluated through multisoftware elastic comparative analysis, DBE performance checking, MCE elastoplastic time‐history analysis, and solid finite‐element simulation of critical joints. Results indicate that the torsional‐to‐translational period ratio of the asymmetric twin‐tower project is reduced to 0.42 via the zoning layout method; the maximum MCE interstory drift ratio across all cases is controlled within 1/147; and the frame shear‐adjustment factor for inclined‐column floors increases by 15%–17% after correction. The proposed thresholds and classifications should be interpreted as preliminary engineering recommendations for similar 7° seismic‐fortification projects up to ~209 m (the tallest investigated case), rather than universally validated design rules. This work provides a reproducible technical reference and identifies the experimental and parametric studies required for broader generalization.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers