Cardiac output and stroke volume dissociate during fluid loading in conscious sheep.
Terry O'Brien, Robert G Hahn
TOB1 Consulting Ltd, London, United Kingdom. · Karolinska Institutet at Danderyds Hospital (KIDS), Stockholm, Sweden.
Key points
From the paper's conclusion- In the conscious animal a fluid-induced rise in cardiac output can be carried entirely by an autonomic, Bainbridge-type tachycardia while stroke volume falls, and need not improve oxygen delivery or arterial pressure.
Abstract
Background. A fluid challenge is judged by a rise in stroke volume or cardiac output, on the twin assumptions that the two report the same physiological effect and that either reflects circulatory benefit. We tested these assumptions across a fourfold crystalloid load in conscious sheep with intact autonomic reflexes. Methods. We performed a secondary analysis of 26 intravenous infusions of 0.9% saline (25, 50 or 100 mL·kg-1 over 20 min) in 13 conscious splenectomized sheep, a within-animal crossover. Cardiac output, arterial and central venous pressures and blood hemoglobin were recorded and mean systemic filling pressure was estimated by the Parkin analogue. Results. Stroke volume and cardiac output dissociated with dose. At 100 mL·kg-1 cardiac output rose +75% carried entirely by heart rate (+143%) while stroke volume fell -25%; across the crossover cardiac output and heart rate scaled with dose, whereas stroke volume showed a non-significant monotonic decline (Friedman p = 0.22). Arterial pressure was the most defended variable, held to a ~16% ceiling by a load-scaled vasodilation (resistance -35% at the highest load). The flow gains barely raised oxygen delivery, which fell 8-14% below baseline by 180 min as hemoglobin was diluted. Filling pressure rose about threefold more than blood volume at every dose. Conclusions. In the conscious animal a fluid-induced rise in cardiac output can be carried entirely by an autonomic, Bainbridge-type tachycardia while stroke volume falls, and need not improve oxygen delivery or arterial pressure. A favorable stroke-volume reading is not a surrogate for systemic flow, and flow for oxygen delivery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stroke-Volume Response to a Standardized Fluid Challenge in Healthy Term Parturients: A Prospective Pilot Study.Journal of personalized medicine · 2026
- Effects of two different fluid rates on tissue oxygenation and haemodynamic stability in anaesthetised horses.Equine veterinary journal · 2026
- Precision fluid therapy in sepsis: fluid responsiveness vs. fluid tolerance.Frontiers in medicine · 2026
- Influence of adrenergic drugs and volume loading on mean systemic filling pressure in non-septic and septic sheep.Frontiers in medicine · 2026
- Arterial dP/dtmax Response to Fluids and Norepinephrine During Intraoperative Hypotension: A Prospective Physiological Study.Journal of clinical medicine · 2026
- Albumin kinetics, intravascular fluid volume, and respiratory function in pigs ventilated at different levels of mechanical power following crystalloid vs. albumin infusionIntensive Care Medicine Experimental · 2026