Albumin kinetics, intravascular fluid volume, and respiratory function in pigs ventilated at different levels of mechanical power following crystalloid vs. albumin infusion
Simone Gattarello, Gaetano Gazzé, Emanuele Rollo, Beatrice Donati, Martina Caronna, Ilaria Grava, Carlo Chiumiento, Zhe Li,
University of Göttingen · Universitätsmedizin Göttingen
Key points
From the paper's conclusion- This study investigates, in healthy pigs, the effects of a 48-h albumin infusion on intravascular fluid volume, albumin kinetics, and its impact on respiratory function.
Abstract
Abstract Background The rationale of albumin use lies in its potential to increase oncotic pressure and optimize tissue perfusion. Randomized trials have not demonstrated a survival benefit, and the effects of albumin on volemia remain unclear. This study investigates, in healthy pigs, the effects of a 48-h albumin infusion on intravascular fluid volume, albumin kinetics, and its impact on respiratory function. Methods Thirty-nine healthy female pigs ventilated for 48 h were grouped according to mechanical power (high ~ 18 J/min vs. low ~ 6 J/min) and type of fluid (5% albumin solution vs. crystalloid), generating four experimental groups: MP LOW -Crystalloid; MP LOW -Albumin; MP HIGH -Crystalloid; and MP HIGH -Albumin. Results Intravascular fluid volume was similar across groups (MP LOW -Crystalloid: 1.92 (± 0.38)L; MP HIGH -Crystalloid: 1.72 (± 0.40)L; MP LOW -Albumin: 1.86 (± 0.37)L; MP HIGH -Albumin: 2.10 (± 0.58)L; p 0.389). For the same mechanical power, the fraction of albumin lost from the plasma was higher in the albumin compared to the crystalloid groups (MP LOW -Albumin: 62 (± 13)% vs. MP LOW -Crystalloid: − 16 (± 66)%; and MP HIGH -Albumin: 58 (± 24)% vs. MP HIGH -Crystalloid: 29 (± 14)%; p < 0.001). Albumin groups showed greater ascites (MP LOW -Crystalloid: 261 (± 380)mL; MP HIGH -Crystalloid: 144 (± 148)mL; MP LOW -Albumin: 710 (± 664)mL; MP HIGH -Albumin: 685 (± 651)mL; p 0.034), and worse end-expiratory lung gas volume and elastance, despite comparable histological damage. Conclusions In our cohort, prolonged albumin infusion did not lead to a difference in intravascular fluid volume, but it resulted in the loss of ~ 60% of the infused albumin and ascites development. Ascites was associated with lower end-expiratory lung gas volume and higher elastance, despite similar histological lung damage across the groups.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of Human Serum Albumin Infusion on Microcirculation, Capillary Leakage, and Endothelial Function in Sepsis Patients: A Retrospective Cohort StudyShock · 2025
- Impact of early albumin therapy on 28-day survival in ICU patients with septic shock concurrent hypoalbuminemia: a retrospective analysis of combined clinical datasets.World journal of emergency medicine · 2026
- The Acid-Base Effects of Albumin in Sepsis: Reconciling the Stewart Physicochemical Approach with the Traditional Buffer-Base Paradigm.Journal of clinical medicine · 2026
- Estimating the Starling equation parameters in living humans by using volume kinetic analysis.Pflugers Archiv : European journal of physiology · 2026
- Albumin Replacement Therapy in Septic Shock: A Randomized Clinical Trial.JAMA network open · 2026
- Effects of tonicity and composition of intravenous maintenance fluid therapy on sodium and water homeostasis in a porcine model of controlled hemorrhage and resuscitation: a randomized study.Intensive care medicine experimental · 2026