A Context-Aware Framework for Optimal Filter Parameter Selection: Enhancing PRV Estimation in Wearable Wrist PPG Signals
Yuna Naito, Natasha Yamane, Aarti Sathyanarayana, Matthew S. Goodwin, Varun Mishra
Key points
From the paper's conclusion- We instantiate this framework using models that gate segments by signal quality and select band-pass cutoff frequencies for each window.
Abstract
Wearable biosensing allows for continuous monitoring and intervention in daily settings. Wrist photoplethysmography (PPG) is a commonly used method for measuring cardiac activity ambulatorily. A typical data preprocessing step is to apply a fixed, one-size-fits-all band-pass filter before peak detection and pulse rate variability (PRV) calculation. However, our analyses reveal that fixed filtering can cause significant errors in PRV estimation even with minimal motion artifacts, and the best filter settings differ across individuals and contextual states. Based on these findings, we introduce a person- and context-aware framework to adaptively select filter parameters at a window level. We instantiate this framework using models that gate segments by signal quality and select band-pass cutoff frequencies for each window. In tests across three datasets, our adaptive method improved PRV (RMSSD) accuracy by up to 279ms compared to a fixed filter and enhanced stress detection. It also increased the amount of usable inter-beat intervals without losing accuracy. Our collective results suggest shifting focus from solely removing motion artifacts toward adaptive selection of filter configurations that considers who is being measured and their state.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Cluster-Based Approach for PPG Signal Preprocessing: Motion Artifact Filtering and Ambient Light Correction.Sensors (Basel, Switzerland) · 2026
- Reliable wrist PPG monitoring by mitigating poor skin sensor contactScientific Reports · 2025
- Reduction of Motion Artifacts in Cardiorespiratory Vital Signs as Oxygen Saturation and Non-Invasive Blood Pressure Through Redundant Denoising and Adaptive Filtering Methods for Wearable Healthcare Monitoring SystemsCardiovascular Engineering and Technology · 2026
- Accuracy of Photoplethysmography-Derived Pulse Rate Variability Compared with Electrocardiography-Derived Heart Rate Variability: A Systematic Review and Meta-Analysis.Sensors (Basel, Switzerland) · 2026
- Context-Augmented, Session-Calibrated Blood Pressure Tracking from PhotoplethysmographyarXiv · 2026
- Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical TranslationarXiv · 2026