Accuracy and operational performance of computer-aided detection software use cases for TB screening: a retrospective comparative evaluation in Ho Chi Minh City, Viet Nam.
Andrew James Codlin, Thang P Dao, Luan Nguyen Quang Vo, Rachel Forse, Binh H Nguyen, Phuong N Trinh, Ha Thi Minh Dang, Lan H Nguyen,
Friends for International Tuberculosis Relief, Ha Noi, Viet Nam. · Pham Ngoc Thach Hospital, Ho Chi Minh City, Viet Nam.
Key points
From the paper's conclusion- No single CAD software use case optimally balanced accuracy and operational efficiency. CAD-only and independent double reading maximised TB detection, while sequential reading improved efficiency and conserved resources. CAD software deployment should align with local workforce capacity, diagnostic infrastructure and programmatic priorities. Prospective evaluations of these use cases are warranted.
Abstract
BACKGROUND: Human reader variability and workforce constraints limit the quality and scale of chest X-ray (CXR) screening for tuberculosis (TB) in many high-burden settings. Although the WHO endorses computer-aided detection (CAD) software, most evaluations have focused on the use case where CAD software entirely replaces human readers. Evidence on alternate CAD software deployment models for TB screening and head-to-head comparisons remains limited. METHODS: A test library of 1466 CXR images was curated after an active case finding initiative in Ho Chi Minh City, Viet Nam. Images were processed by Lunit INSIGHT CXR CAD software and independently interpreted by 10 human readers across two rounds separated by a wash-out period. Five CXR interpretation methods were simulated: human-only reading, CAD-only reading, CAD-assisted human reading, independent double reading and sequential reading. Generalised estimating equations were used to estimate adjusted incidence rate ratios comparing the sensitivity and specificity of CAD-containing CXR interpretation methods with human-only reading, while operational performance metrics were summarised as percentage changes relative to human-only reading. RESULTS: Human-only reading achieved mean sensitivity 79.0% and specificity 84.8%. CAD-only reading significantly increased sensitivity (91.4%, adjusted incidence rate ratio (aIRR) 1.16, 95% CI 1.06 to 1.27, p=0.002) and significantly reduced specificity (81.9%, aIRR 0.96, 95% CI 0.94 to 0.98, p<0.001). Independent double reading achieved the highest sensitivity (95.0%, aIRR 1.20, 95% CI 1.12 to 1.30, p<0.001), but the lowest specificity (74.5%, aIRR 0.87, 95% CI 0.86 to 0.89, p<0.001) and increased diagnostic testing by +59.2% and the number needed to test by +32.3%. Sequential reading maintained sensitivity comparable to human-only reading (78.8%, aIRR 1.00, 95% CI 0.99 to 1.00, p=0.326), while achieving the highest specificity (90.3%, aIRR 1.07, 95% CI 1.06 to 1.07, p<0.001), reducing human workload by -67.5%, and lowering the number needed to test by -29.9%. CAD-assisted human reading produced non-significant sensitivity gains (82.9%, aIRR 1.05, 95% CI 1.00 to 1.11, p=0.057) and reduced specificity (82.2%, aIRR 0.97, 95% CI 0.96 to 0.98, p<0.001), with substantial inter-reader variability. Sensitivity gains were greatest among participants without prior TB, and specificity improvements were most pronounced among less experienced readers. CONCLUSION: No single CAD software use case optimally balanced accuracy and operational efficiency. CAD-only and independent double reading maximised TB detection, while sequential reading improved efficiency and conserved resources. CAD software deployment should align with local workforce capacity, diagnostic infrastructure and programmatic priorities. Prospective evaluations of these use cases are warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of computer-aided detection products in community and facility tuberculosis screening: 2025 policy update.ERJ open research · 2026
- Combining Sputum Pooling and Automated Chest X-Ray Evaluation in Efficient Algorithms for Tuberculosis Active Case Finding: A Simulation Study.Open forum infectious diseases · 2026
- Cost-effectiveness analysis of computer aided detection for tuberculosis in Ghana: A decision-analytic modeling study.PloS one · 2026
- Comparative cost analysis of community-based tuberculosis screening: Computer-Aided Detection (CAD) alone versus CAD with point-of-care C-reactive protein testing in South Africa and Lesotho.PLOS global public health · 2026
- Implementation of Digital Chest X-Ray with Computer-Aided Detection for Tuberculosis Screening Among Persons with Advanced HIV Disease in Maputo, Mozambique: A Retrospective Cohort Analysis.Diagnostics (Basel, Switzerland) · 2026
- Beyond overall accuracy: subgroup performance and threshold calibration of AI-assisted chest radiography for equity-oriented pulmonary tuberculosis screening.Frontiers in medicine · 2026