Diagnostic performance of an open-source artificial intelligence model for detecting chest infections on after-hours emergency department chest radiographs in Singapore.
Ying Jie Toh, Samantha Ying Ying Tan, Chin Wah Eng, Boon Kee Lee, Praveen M Yogendra, Min On Tan
Department of Radiology, Sengkang General Hospital, Singapore tohyingjie@gmail.com. · Department of Radiology, Sengkang General Hospital, Singapore.
Key points
From the paper's conclusion- CheXNeXt demonstrated favourable performance and potential as a triage support tool to alleviate ED CXR workloads. Further external validation and real-world integration studies are required to assess generalisability and clinical impact.
Abstract
OBJECTIVES: Chest X-rays (CXRs) are essential for diagnosing chest infections in emergency departments (EDs), particularly after-hours when radiologist availability is limited. This study evaluates the diagnostic performance of a free, open-source artificial intelligence (AI) model, CheXNeXt, in detecting pulmonary infections on after-hours ED CXRs in Singapore. METHODS: This retrospective study analysed 1006 anonymised after-hours ED CXRs using CheXNeXt, which generated probabilities for consolidation, pneumonia and pleural effusion. Outputs were converted to binary predictions using published thresholds and compared against radiologists’ reports as the reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the receiver operating characteristic curve (AUC) were calculated. RESULTS: CheXNeXt achieved: for consolidation, sensitivity 0.234, specificity 0.990, PPV 0.846, NPV 0.849 and AUC 0.900; for pneumonia, sensitivity 0.176, specificity 0.995, PPV 0.889, NPV 0.845 and AUC 0.856; for pleural effusion, sensitivity 0.622, specificity 0.949, PPV 0.656, NPV 0.942 and AUC 0.916. Sensitivity for consolidation, pneumonia and pleural effusion increased to 0.894, 0.681 and 0.852 while maintaining acceptable specificity of 0.765, 0.881 and 0.848, respectively, following Youden index threshold optimisation. DISCUSSION: The AI demonstrates high specificity but limited sensitivity at default thresholds. Performance improved following threshold optimisation, highlighting the importance of AI calibration prior to clinical deployment. Limitations include single-radiologist reporting with radiographic findings as surrogate for infection, reflecting real-world ED practice. CONCLUSION: CheXNeXt demonstrated favourable performance and potential as a triage support tool to alleviate ED CXR workloads. Further external validation and real-world integration studies are required to assess generalisability and clinical impact.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial intelligence (AI)-driven ensemble model for comprehensive chest X-ray abnormality detection and deploymentThe Indian Journal of Medical Research · 2026
- How threshold customisation affects the performance of a multiclass X-ray AI model for primary care triage: a retrospective studyBMJ Open · 2026
- Default-threshold operating-point validation of a commercial chest radiograph AI system for selected CT-anchored thoracic findings: a bi-national multicenter retrospective study.Scientific reports · 2026
- AI-based clinical prediction model for early infectious disease classification in the emergency department.Frontiers in artificial intelligence · 2026
- Artificial Intelligence-Based Automated Detection of Chest X-ray Abnormalities as Support for Young Radiologists.Current medical imaging · 2026
- Artificial Intelligence-Assisted Chest Radiography: A Prospective Crossover Multi-Reader Study on Diagnostic Performance and Workflow Efficiency.Academic radiology · 2026