Association of treponemal chemiluminescent immunoassay signal intensity with TPPA reactivity in reverse sequence syphilis screening.
Xin Liu, Shuping Tian, Jinli Lou, Hui Liu, Xia Feng, Yu Li, Feifei Jiang, Yuhan Duan,
Beijing YouAn Hospital, Capital Medical University, Beijing, China. · School of Biomedical Sciences, Shandong First Medical University, Jinan, Shandong, China.
Key points
From the paper's conclusion- These findings demonstrate that, within the analytical conditions of this study, higher assay-specific COI values were associated with a greater likelihood of TPPA reactivity.
Abstract
UNLABELLED: Reverse sequence screening for syphilis using treponemal chemiluminescent immunoassays (Tp-CIAs) is widely used in clinical laboratories; however, interpretation is typically based on binary cutoff values, and the clinical value of signal intensity remains underutilized. We conducted a retrospective diagnostic performance accuracy study including 1,827 individuals undergoing routine screening to evaluate the clinical utility of the Tp-CIA cutoff index (COI) as a continuous variable, using the TPPA as the reference standard. ROC analysis was performed to determine the optimal cutoff, and associations between COI values and TPPA reactivity were assessed. Tp-CIA demonstrated excellent discrimination of TPPA reactivity (area under the curve 0.992). COI values showed a strong monotonic association with TPPA reactivity (Spearman rs = 0.855), increasing from 2.5% at a COI <1 to 99.8% at a COI ≥30. An exploratory cutoff of COI = 3.25 increased specificity from 88.6% to 96.4%, with a corresponding decrease in sensitivity from 99.1% to 95.9%, compared with the manufacturer-recommended cutoff of 1.0. Discordant results (3.9%) were largely confined to low COI values, whereas high COI values were strongly associated with TPPA reactivity. Diagnostic performance remained consistent across HIV subgroups. Among individuals with concurrent non-treponemal testing, COI values were positively correlated with ordered rapid plasma reagin (rs = 0.637) and toluidine red unheated serum test (rs = 0.705) titer levels. These findings demonstrate that, within the analytical conditions of this study, higher assay-specific COI values were associated with a greater likelihood of TPPA reactivity. COI-based interpretation should remain supplementary to established confirmatory testing and clinical assessment; exploratory threshold requires independent analytical and clinical validation. IMPORTANCE: Syphilis remains a growing global public health concern, and reverse sequence screening using Treponema pallidum chemiluminescent immunoassay (Tp-CIA) is widely adopted. Although these assays are interpreted qualitatively using manufacturer-defined cutoffs, the underlying signal intensity varies across specimens. In this study cohort, increasing Tp-CIA cutoff index (COI) values were associated with an increasing observed proportion of TPPA-reactive results. This association was assay- and cohort-specific and should be interpreted descriptively. COI should not replace established confirmatory testing, quantitative non-treponemal testing, or clinical assessment, and its potential supplementary value requires independent analytical and clinical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinal quantitative treponemal-specific immunoassay patterns in syphilis reinfection among MSM living with HIV.Sexually transmitted infections · 2026
- Stage-Specific Associations of Automated RPR With Treponema pallidum qPCR Positivity and Cycle Threshold in Early Symptomatic Syphilis: A Multicenter Study Using Specimens Collected During Routine CaremedRxiv · 2026
- Discordant serological results in people with HIV and syphilis: Treponemal Seroreversion versus False-Positive Reactivity.Sexually transmitted diseases · 2026
- Revisiting Anti-HCV Seropositivity: Signal Intensity, Diagnostic Uncertainty, and the Limitations of Fixed Cut-Offs.Diagnostics (Basel, Switzerland) · 2026
- Evaluation of Dual Path Platform optical density in relation to RPR titers and serological response in syphilis: a cross-sectional and longitudinal study.International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases · 2026
- B-405 Estimation of reference change value for the cyclosporine assay and implementation of delta check auto verificationClinical Chemistry · 2026