A model-based analysis of modulation masking effects on vocoded speech intelligibility.
Cathrina Veigel, Helia Relaño-Iborra, Andrew J Oxenham, Torsten Dau
Hearing Systems, Department of Health Technology, Technical University of Denmark, Kongens Lyngby 2800, Denmark. · Department of Psychology, University of Minnesota, Minneapolis, Minnesota 55455, USA.
Key points
From the paper's conclusion- These findings support the view that modulation masking is not the primary limitation in simulated electric hearing and point to envelope-energy and pitch-related distortions as important targets for future cochlear implant-oriented intelligibility models.
Abstract
Vocoded speech is widely used to simulate aspects of cochlear implant listening, and modeling vocoded intelligibility in normal-hearing listeners can provide insight into auditory processing under electric hearing. Sentence recognition was measured using three masker types (speech-shaped noise, tone complex, and noise-modulated tone complex) and four processing conditions (unprocessed, bandpass-filtered, tone-vocoded, and tone-vocoded with simulated current spread). Masker type affected intelligibility in all conditions except vocoded speech with simulated current spread. A modified speech-based envelope power spectrum model with a correlation-based decision stage was fitted to the unprocessed speech-shaped-noise condition and then applied, without re-fitting, to the remaining conditions. The model captured masker-dependent intelligibility patterns for unprocessed, bandpass-filtered, and tone-vocoded speech without simulated current spread. Analyses of the model's internal representations suggested that vocoding-related intelligibility loss was driven mainly by the removal of higher-rate temporal-envelope modulations rather than by reduced spectral resolution. With simulated current spread, the model predicted the loss of benefit for unmodulated maskers but consistently overestimated intelligibility. These findings support the view that modulation masking is not the primary limitation in simulated electric hearing and point to envelope-energy and pitch-related distortions as important targets for future cochlear implant-oriented intelligibility models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Perception of emotions in compressed speech by cochlear implant usersFrontiers in Audiology and Otology · 2026
- From Approximation to Validation: Rethinking Frequency-Matched Acoustic Models of Cochlear Implants.Ear and hearing · 2026
- Recognition of noise-vocoded accented speech by non-native listeners.Phonetica · 2026
- Leveraging Self-Supervised Audio-Visual Pretrained Models to Improve Vocoded Speech Intelligibility in Cochlear Implant SimulationIEEE Transactions on Biomedical Engineering · 2025
- Perceived sound quality and speech recognition are not interchangeable outcome measures in adult cochlear implant users.Frontiers in human neuroscience · 2026
- The voice clone intelligibility benefit in noise in middle-aged listeners.JASA express letters · 2026