Does access to deep learning uncertainty improve task performance in human readers?
Cheng Ting Lin, Shudong Li, Craig K Abbey, Patrick Li, Leonid Roshkovan, Satomi Kawamoto, Hersh Sagreiya, Julianna Czum,
Johns Hopkins University, Department of Radiology and Radiological Science, Baltimore, Maryland, United States. · Johns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.
Key points
From the paper's conclusion- Results from the study provide initial evidence that radiologists can use information from multiple posterior samples to improve task-based imaging performance.
Abstract
PURPOSE: Deep learning image reconstruction or restoration can produce visually high-quality images that may lack familiar visual cues of reliability. Diffusion posterior sampling (DPS) is a stochastic reconstruction algorithm capable of producing samples from the posterior distribution, offering a potential mechanism to communicate uncertainty and a representation of the posterior distribution to radiologists. We designed and conducted an observer study to evaluate whether displaying multiple DPS posterior samples improves task-based performance in human readers compared with displaying a single DPS sample. APPROACH: The observer study evaluated performance for a binary discrimination task involving spiculated and non-spiculated lung lesions. A total of 200 lung lesions were obtained from the Lung Image Database Consortium dataset, including 100 spiculated and 100 non-spiculated lesions. Computed tomography slices containing these lesions were treated as ground truth. Low-dose projection data were simulated and reconstructed using filtered backprojection and DPS. Six radiologists evaluated each case under four display conditions: low-dose filtered backprojection, a single DPS sample, a scrollable stack of 30 DPS samples, and a tiled display of the same 30 DPS samples. Observer performance was assessed using multi-reader multi-case receiver operating characteristic (ROC) analysis, with Lung Image Database Consortium spiculation annotations used as ground truth. Reading time and reader confidence were also recorded. RESULTS: Pooled area under the ROC curves (AUCs) were 0.691 for low-dose filtered-backprojection (FBP), 0.713 for single-sample DPS, 0.750 for the scrollable stack, and 0.747 for the tiled display. Both multi-sample DPS displays improved pooled AUC relative to single-sample DPS at the 10% significance level. The better-performing multi-sample display was reader-dependent. Multi-sample displays were also associated with higher reader confidence than single-sample DPS and FBP displays. Multi-sample displays generally increased reading time, although there was a wide reader-dependent variability in reading time and in which multi-sample display was most time consuming. Averaged over all readers, the scrollable stack and tiled displays increased average reading time by 34.6% and 55.8% relative to low-dose FBP, respectively. CONCLUSIONS: Results from the study provide initial evidence that radiologists can use information from multiple posterior samples to improve task-based imaging performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mixed Prior Diffusion Posterior Sampling for High Resolution CT Reconstruction.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2026
- Deep-learning image reconstruction algorithms for CT: A task-based image quality assessment of four CT systems using a phantomDiagnostic and Interventional Imaging · 2026
- Physical image quality of normal- and super-resolution deep learning reconstruction in lung CT: a task-based phantom study.Physical and engineering sciences in medicine · 2026
- Deep Learning Quality Control for RECIST-Oriented Assessment: A Vision Transformer Predicts Inter-Reader Variability of Unidimensional Lesion Measurements on Contrast CT.Cancers · 2026
- Deep Learning Super-Resolution CT Versus Ultra-High-Resolution CT: A Direct Comparison in Cadaveric Human Lungs.Academic radiology · 2026
- SpatialUQ: Post-Hoc Uncertainty Quantification from Spatial Consistency in Black-Box Vision ModelsarXiv · 2026