Does ceiling-fan use modify circulating markers of heat-related stress in bed-resting older adults?
Glen P Kenny, Kelli E McCormick, Fergus K O'Connor, James J McCormick
Human and Environmental Physiology Research Unit, School of Human Kinetics, University of Ottawa, Ottawa, Ontario, Canada.
Key points
From the paper's conclusion- We examined circulating stress biomarkers in 20 older adults (12 females; median age 71 years), who completed randomized 8 h exposures to 31°C and 45% relative humidity while remaining reclined beneath a ceiling fan delivering 0 m s −1 (control) or 1.5 m s −1 (fan).
Abstract
Ceiling fans are a low-energy strategy for reducing heat strain, but their ability to protect against subclinical cellular and organ stress is unknown. We examined circulating stress biomarkers in 20 older adults (12 females; median age 71 years), who completed randomized 8 h exposures to 31°C and 45% relative humidity while remaining reclined beneath a ceiling fan delivering 0 m s-1 (control) or 1.5 m s-1 (fan). Venous blood was collected before and after each exposure and analysed for serum intestinal fatty acid-binding protein (IFABP), soluble cluster of differentiation 14 (sCD14), kidney injury molecule-1, neutrophil gelatinase-associated lipocalin, tumour necrosis factor-α, interleukin-6 and C-reactive protein. Core temperature and heart rate were measured continuously. Biomarker responses were assessed using baseline-adjusted linear mixed-effects models with Holm correction for multiple testing. Fan use lowered peak core temperature and heart rate by 0.2°C (P < 0.001) and 5 beats min-1 (P = 0.030), respectively. The adjusted difference in IFABP change between control and fan was 344 pg mL-1 [95% confidence interval: 102-586] (unadjusted P = 0.005; Holm-adjusted P = 0.035). Across conditions, the estimated changes in IFABP and sCD14 were 240 pg mL-1 [95% confidence interval: 11-468] (Holm-adjusted P = 0.240) and 0.57 ng mL-1 [95% confidence interval: 0.10-1.03] (Holm-adjusted P = 0.119), respectively. No other biomarker comparisons remained significant after Holm adjustment. Ceiling-fan use at 31°C attenuated the IFABP response in bed-resting older adults despite modest effects on core temperature and heart rate. These exploratory findings suggest that fan-mediated protection might extend beyond changes captured by conventional physiological measures, but confirmation in prospectively powered studies incorporating direct measures of gastrointestinal permeability is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of ceiling fan use on cardiovascular autonomic function during simulated indoor overheating in bed-resting older adults.Experimental physiology · 2026
- O060. Electric Fan Use Increases Total Sleep Time At 35°CSLEEP advances · 2026
- P162. Electric Fan Use Reduces Thermal Discomfort but Not Sleep QualitySLEEP advances · 2026
- Acute exertional heat stress alters both pro- and anti-inflammatory blood markers: A meta-analysis.Temperature (Austin, Tex.) · 2026
- Core Temperature Responses During Passive Heat Exposure Differentiate Mice Previously Exposed to Exertional Heat Stroke and Endotoxemia.American journal of physiology. Regulatory, integrative and comparative physiology · 2026
- Gastrointestinal temperature of elite and recreational adult runners during a 100-mile ultramarathon under heat exposure.Physiological reports · 2026