P162. Electric Fan Use Reduces Thermal Discomfort but Not Sleep Quality
C Teng, H Brown, E Machan, C Gordon, T Doan, G Ng, O Jay, J Smallcombe,
Key points
From the paper's conclusion- Regression analyses indicated no association between sleep quality and thermal measures except for recalled discomfort (β = −0.77, p=0.031), such that greater reductions in thermal discomfort were associated with improvements in sleep quality.
Abstract
Background Electric fan use is a widely accessible cooling strategy during hot nights; however, its effectiveness under extreme ambient temperatures (≥35°C) remains debated. It is unclear whether sustained fan use at these temperatures results in meaningful improvements in thermal discomfort and sensation, and perceived sleep quality during prolonged overnight exposure. Methods In a repeated-measures crossover design, participants are completing overnight conditions with fan ON and OFF (target n=30). Interim analyses are presented from 26 participants. Outcomes included thermal discomfort and sensation assessed prior to lights-out (last) and by morning recall, alongside perceptual sleep measures from the Pittsburgh Sleep Diary (PSD; quality, latency, mood, alertness), all quantified using 100 mm visual analogue scales (VAS). Linear mixed models estimated ON–OFF differences adjusted for sex and sequence. Secondary analyses used linear regression to examine associations between changes in thermal responses and sleep outcomes. Results Fan use reduced thermal discomfort at lights-out (−15.96; p=0.001) and recall (−14.77; p=0.002), and reduced thermal sensation at both lights-out (−5.01; p=0.043) and recall (−7.29; p=0.005). Despite these improvements, no overall changes were observed in sleep quality or latency (p≥0.13 in all). Regression analyses indicated no association between sleep quality and thermal measures except for recalled discomfort (β = −0.77, p=0.031), such that greater reductions in thermal discomfort were associated with improvements in sleep quality. Conclusions Fan use improves nocturnal thermal responses but does not consistently translate into better perceived sleep; benefits appear modest and selectively linked to recalled discomfort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- O060. Electric Fan Use Increases Total Sleep Time At 35°CSLEEP advances · 2026
- Air Movement and Sleep Quality in the Built Environment: A Systematic ReviewBuildings · 2026
- Does ceiling-fan use modify circulating markers of heat-related stress in bed-resting older adults?Experimental physiology · 2026
- Indoor heat and sleep quality: building and occupant modifiers in the HeatwiseSweden cohortEuropean Journal of Public Health · 2026
- Effects of ceiling fan use on cardiovascular autonomic function during simulated indoor overheating in bed-resting older adults.Experimental physiology · 2026
- Associations between survey-based thermal comfort, sensor-based indoor temperature, and sleep health in a cross-sectional study of children in Boston, Massachusetts.Sleep health · 2026