Cervical articular process joint versus ventral cervical stabilization in horses: A biomechanical study.
Machiel P Ysebaert, Ryan Foslien, Donovan M David, Andres F Bonilla, Ben C Gadomski, Jeremiah T Easley, Brad B Nelson
Colorado State University, College of Veterinary Medicine and Biomedical Sciences, Fort Collins, Colorado, USA. · Orthopedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, Colorado, USA.
Key points
From the paper's conclusion- Bilateral APJ stabilization demonstrated greater stiffness than VCS with comparable failure moments.
Abstract
OBJECTIVE: To determine the biomechanical properties and modes of failure of a single level equine cervical spine immobilized with unilateral or bilateral articular process joint (APJ) stabilization, ventral cervical stabilization (VCS) and non-stabilized controls. STUDY DESIGN: Ex vivo experimental study. SAMPLE POPULATION: A total of 24 equine cadaver cervical spines. METHODS: Cervical spinal units (C4-C5) were randomly assigned to four groups (n = 6/group): unilateral APJ stabilization, bilateral APJ stabilization, VCS using pedicle screws and rod constructs, or non-stabilized. Non-destructive testing assessed kinematic range of motion (ROM), neutral zone, and stiffness in flexion-extension, axial rotation, and lateral bending. Specimens underwent four-point bending to failure (0.1 mm/s). Radiographs and visual inspection characterized failure mode. Groups were compared using one-way ANOVA or Kruskal-Wallis tests. Significance was p < .05. RESULTS: Non-destructive testing showed unilateral and bilateral APJ constructs were stiffer in flexion-extension, axial rotation and lateral bending than non-stabilized (p < .05). In destructive testing, bilateral APJ stabilization was 2.5× stiffer than VCS, with similar failure moments. Construct stiffness was higher with bilateral APJ stabilization (27.89 ± 5.11 Nm/°) versus non-stabilized (6.92 ± 3.90 Nm/°, p = .0037), unilateral APJ (14.06 ± 2.94 Nm/°, p < .0001) and VCS (11.28 ± 3.01 Nm/°, p < .0001) groups. Failure typically occurred as cranial articular process fracture in both bilateral and unilateral APJ constructs. CONCLUSION: Bilateral APJ stabilization demonstrated greater stiffness than VCS with comparable failure moments. CLINICAL SIGNIFICANCE: Bilateral APJ stabilization, with its higher stiffness than VCS, may be an alternative strategy to achieve spinal fusion in horses while avoiding a ventral surgical approach. Future investigations and development of this technique in vivo are warranted before implementation in clinical cases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cadaveric feline study revealed no significant difference in biomechanical stability following L4-L5 hemilaminectomy versus mini-hemilaminectomy.American journal of veterinary research · 2026
- Biomechanical Comparison of Skip Laminectomy and Laminoplasty in the Lower Cervical Spine: An Experimental Study Using a Sheep Model.Clinical spine surgery · 2026
- Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion.Global spine journal · 2026
- FiberWire as a Non-Metallic Binding Material for Dorsal K-Wire Spinal Stapling: An Ex Vivo Rabbit Thoracolumbar Biomechanical Study.Veterinary sciences · 2026
- EXPRESS: Biomechanical evaluation of feline sacroiliac joint stabilization using a single short cannulated compression headless screw: A cadaveric study.Journal of feline medicine and surgery · 2026
- The destabilizing effect of cervical foraminotomy - an ex vivo biomechanical study.The spine journal : official journal of the North American Spine Society · 2026