Journal of feline medicine and surgery

EXPRESS: Biomechanical evaluation of feline sacroiliac joint stabilization using a single short cannulated compression headless screw: A cadaveric study.

Matthias Kornmayer, Laura Wachsmuth, Yury Zablotski, Christoph Thorwaechter, Josef Wieser

LMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Ludwig-Maximilians-Universität München, Munich, Germany. · Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Germany.

Key points

From the paper's conclusion
  • A single CCHS engaging 40 % of the sacral width provides interfragmentary compression and rotational stability comparable to that of screws engaging 60 % of the sacral width lengths under the specific ex vivo testing conditions used in the feline SIL model.

Abstract

OBJECTIVES: The aim of this study was to compare interfragmentary compression and rotational stability achieved with a single short cannulated compression headless screw (CCHS) with those obtained using longer CCHSs and cortical lag screws in a feline sacroiliac luxation (SIL) model. METHODS: In this experimental study, 12 cadavers of adult domestic short-haired cats with a simulated unilateral SIL were stabilized using a single 2.5 mm CCHSs engaging 40 % of the sacral width and mounted in a mechanical testing machine. To assess compressive forces, pressure-mapping sensors were inserted into the joint space before fracture reduction. Total force (N), area of compression (mm2), and total pressure (N/mm2) were recorded. For rotational mechanical testing, the pelves were subsequently loaded through the acetabulum to replicate hindlimb ground reaction forces. A constant displacement rate of 0.5 mm/s was applied until maximal failure. Yield and ultimate load, stiffness, and failure modes were recorded. Results were compared with previously obtained data for CCHSs and cortical lag screws engaging 60 % of the sacral width. Group comparisons were conducted using Fischer's ANOVA and Kruskal-Wallis tests. Post-hoc pairwise comparisons were conducted using Student's t-tests and the Dunn test. Statistical significance was set at p < 0.05. RESULTS: No statistically significant differences were identified among groups or in pairwise comparisons for total force (p=0.35), area of compression (p=0.76), total pressure (p=0.37), yield load (p = 0.55), ultimate load (p = 0.82), or stiffness (p = 0.57). All failures occurred due to screw loosening. CONCLUSIONS AND RELEVANCE: A single CCHS engaging 40 % of the sacral width provides interfragmentary compression and rotational stability comparable to that of screws engaging 60 % of the sacral width lengths under the specific ex vivo testing conditions used in the feline SIL model.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

EXPRESS: Biomechanical evaluation of feline sacroiliac joint stabilization using a single short cannulated compression headless screw: A cadaveric study — Science Skim