Contrast‐Enhanced Ultrasonography of Orbital and Intraocular Pathologies in 24 Dogs and 6 Cats
Janneke I. Ortner, Katharina M. Hittmair, Barbara Nell, Klaas‐Ole Blohm
Key points
From the paper's conclusion- Conclusion Findings indicated that CEUS could identify a variety of orbital and intraocular pathologies and provided additional diagnostic information to B‐mode ultrasonography, particularly for assessing neoplastic lesions and retinal detachments.
Abstract
Objective Contrast‐enhanced ultrasonography (CEUS) is a noninvasive and relatively safe imaging technique to assess ocular perfusion, showing high sensitivity and specificity for tumor characterization in human oncology, while reports on its application in canine and feline diseased eyes are limited. This study aimed to describe the CEUS features of orbital and intraocular pathologies in dogs and cats in order to evaluate its diagnostic value in detecting and characterizing various lesions. Animal Studied CEUS examinations of 30 animals (24 dogs, 6 cats) were evaluated retrospectively. Procedures Following B‐mode ultrasonography, CEUS examinations utilizing sulfur hexafluoride were performed. Pathologies were categorized in one of the following groups: orbital neoplastic lesions, orbital inflammatory lesions, intraocular neoplastic lesions, intraocular inflammatory lesions and retinal detachment. Qualitative perfusion parameters, contrast intensity, enhancement pattern, perfusion type and time to wash‐in and wash‐out were evaluated. Results CEUS detected vascularization in orbital and intraocular pathologies, with variable enhancement characteristics. Persistent vascularization was observed in all cases of retinal detachment. In orbital and intraocular neoplastic lesions, CEUS improved lesion localization, assessment of interactions with surrounding tissues and tissue perfusion. For inflammatory pathologies such as abscesses, myositis, and steatitis, the additional diagnostic value of CEUS compared to B‐mode ultrasonography was limited. Conclusion Findings indicated that CEUS could identify a variety of orbital and intraocular pathologies and provided additional diagnostic information to B‐mode ultrasonography, particularly for assessing neoplastic lesions and retinal detachments. CEUS has the potential to enhance ophthalmic ultrasonography in differentiating specific pathologies. Prospective studies are warranted to further evaluate its clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Prospective Observational Study Comparing Contrast-Enhanced Ultrasonography (CEUS) and Magnetic Resonance Imaging (MRI) in Evaluating Adnexal Lesions.Journal of obstetrics and gynaecology of India · 2026
- Does the addition of contrast-enhanced ultrasonography to B-mode ultrasonography improve diagnostic accuracy for breast cancer? A systematic review and meta-analysis.Journal of medical ultrasonics (2001) · 2026
- The added value of contrast-enhanced ultrasonography to BI-RADS in the evaluation of breast lesions presenting with pathological nipple discharge.Quantitative imaging in medicine and surgery · 2026
- The application of ultrasonography in the differential diagnosis of orbital lesions.Frontiers in ophthalmology · 2025
- Pediatric contrast-enhanced ultrasound in clinical practice: evidence maturity and workflow integration.Frontiers in radiology · 2026
- Contrast-enhanced ultrasound for differentiating benign from malignant Breast Imaging Reporting and Data System 4a breast lesions: a prospective diagnostic accuracy study.Gland surgery · 2026