Does the addition of contrast-enhanced ultrasonography to B-mode ultrasonography improve diagnostic accuracy for breast cancer? A systematic review and meta-analysis.
Shotaro Inoue, Kazuaki Nakashima, Kazutaka Nakashima, Tomonari Kunihisa, Koichi Hirokaga, Kaori Tane, Yoshihito Goto, Takeo Nakayama
Division of Breast Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, Japan. · Department of Breast Imaging and Breast Interventional Radiology, Shizuoka Cancer Center Hospital, Nagaizumi, Shizuoka, Japan.
Key points
From the paper's conclusion- Pooled diagnostic estimates were higher in studies evaluating CEUS combined with B-mode ultrasonography than in studies evaluating B-mode ultrasonography alone, particularly by increasing specificity in differentiating benign from malignant breast lesions. However, these findings are based on indirect comparisons and should be interpreted with caution.
Abstract
PURPOSE: This study aimed to determine whether the addition of contrast-enhanced ultrasonography (CEUS) to B-mode ultrasonography improves diagnostic accuracy in differentiating benign from malignant breast lesions. METHODS: A comprehensive literature search was performed using PubMed (MEDLINE), Ichushi, and the Cochrane Library up to July 2025. Eligible studies assessed the diagnostic performance of CEUS for suspected breast cancer, with histopathology as the reference standard. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and positive and negative likelihood ratios were calculated. RESULTS: Eleven studies comprising 1987 patients with 2051 lesions were included. The pooled sensitivity and specificity of B-mode ultrasonography alone were 86.1% (95% confidence interval [CI] 81.5-89.7) and 70.8% (95%CI 60.7-79.2), respectively. For B-mode alone, the pooled DOR was 15.0 (95%CI 9.7-23.3), with an LR + of 2.95 (95% CI 2.18-3.99) and an LR - of 0.20 (95% CI 0.15-0.26). In contrast, CEUS was associated with improved pooled estimates of diagnostic performance, yielding a pooled sensitivity of 93.4% (95%CI 89.0-96.2) and a specificity of 85.8% (95%CI 80.9-89.6). The pooled DOR for CEUS was 86.3 (95%CI 48.0-155.4), with an LR + of 6.59 (95%CI 4.89-8.87) and an LR - of 0.08 (95%CI 0.05-0.13). CONCLUSIONS: Pooled diagnostic estimates were higher in studies evaluating CEUS combined with B-mode ultrasonography than in studies evaluating B-mode ultrasonography alone, particularly by increasing specificity in differentiating benign from malignant breast lesions. However, these findings are based on indirect comparisons and should be interpreted with caution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A New Contrast-Enhanced Ultrasound (CEUS) Reporting and Data System for Breast Lesions.Ultrasound in medicine & biology · 2026
- Contrast-enhanced ultrasound for differentiating benign from malignant Breast Imaging Reporting and Data System 4a breast lesions: a prospective diagnostic accuracy study.Gland surgery · 2026
- The added value of contrast-enhanced ultrasonography to BI-RADS in the evaluation of breast lesions presenting with pathological nipple discharge.Quantitative imaging in medicine and surgery · 2026
- ROI-Based Quantitative Analysis in Contrast-Enhanced Mammography: A Feasibility Study for Reproducible Enhancement Assessment.Diagnostics (Basel, Switzerland) · 2026
- Added Value of Preoperative Contrast Enhanced Mammography in Staging of Malignant Breast Lesions (PROCEM): A Randomized Controlled Trial.Radiology · 2026
- Diagnostic accuracy of ultrasound in detecting pathological complete response to neoadjuvant chemotherapy in breast cancer: a systematic review and diagnostic test accuracy meta-analysis.Gland surgery · 2026