Key points
From the paper's conclusion- In pediatric patients, new-generation ICM implantation was safe, well tolerated, and associated with stable sensing performance. Remote monitoring and reprogramming enabled timely diagnosis and individualized optimization, supporting the clinical utility of contemporary ICMs in this population.
Abstract
BACKGROUND: Insertable cardiac monitors (ICMs) are increasingly used in pediatric patients, yet data on new-generation devices remain limited. The aim of this retrospective study was to describe a single-center real-world experience with a new-generation ICM in pediatric patients, focusing on procedural feasibility, sensing performance, transmission burden, and user experience. METHODS: Consecutive patients aged ≤18 years undergoing LUX-Dx ICM implantation between 2023 and 2025 were included. Procedural characteristics, sensing parameters, transmission patterns, diagnostic yield, reprogramming strategies, and patient/caregiver-reported experience were analyzed. Data are reported as median (25th-75th percentile) or mean ± standard deviation. RESULTS: Twenty-nine patients underwent ICM implantation. Procedures were brief (6 ± 2 min) and complication-free. Electrical parameters were satisfactory and stable at discharge. Follow-up was 18 (6-23) months. A median of 2.7 transmissions per patient-month were received, of which 55% were alerts. Time from arrhythmia detection to transmission was 15 (3-21) hours. The number of episodes per patient was 4.8 (3.1-15.9) per month, with substantial inter-patient variability and bradycardia being the most frequent detection (80%). A diagnostic conclusion was reached in 79% of patients (positive: 45%, negative: 34%) at a median of 3 months. Reprogramming was performed in 90% of patients, mainly remotely (77%), and was predominantly directed toward reducing detection sensitivity. Patient and caregiver acceptance of remote monitoring was high. CONCLUSIONS: In pediatric patients, new-generation ICM implantation was safe, well tolerated, and associated with stable sensing performance. Remote monitoring and reprogramming enabled timely diagnosis and individualized optimization, supporting the clinical utility of contemporary ICMs in this population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-world evaluation of the positive predictive value and transmission burden of a novel implantable cardiac monitor with a remote reprogramming capability: insights from a single-center experienceFrontiers in Cardiovascular Medicine · 2026
- Utility of an automatic and patient-triggered cardiac event recorder: experience in children.BMC pediatrics · 2026
- Long-term safety and efficacy of arrhythmia monitoring with an implantable cardiac monitor.International journal of cardiology · 2026
- Daily Remote Monitoring of Pediatric Patients With Cardiac Implantable Electronic Devices: Early Arrhythmia Detection and Timely Clinical InterventionClinical Case Reports · 2026
- Ambulatory Electrocardiography Modalities in Pediatric Arrhythmia Detection and Management.JAMA pediatrics · 2026
- Diagnostic Yield and Clinical Consequences of Implantable Loop Recorder Monitoring in a Real-World Tertiary Cardiovascular Center Under Restricted Reimbursement.Healthcare (Basel, Switzerland) · 2026