Long-term safety and efficacy of arrhythmia monitoring with an implantable cardiac monitor.
Eimo Martens, Romain Eschalier, Pilar Cabanas, Laurence Jesel, Claudia Amellone, Paul Milliez, Dennis Lau, Andreas Hain,
Klinikum rechts der Isar, München, Germany. Electronic address: eimo.martens@mri.tum.de. · Centre Hospitalier Universitaire Clermort-Ferrand, Clermont Ferrand, France.
Key points
From the paper's conclusion- ICMs continue to deliver clinically meaningful arrhythmia diagnoses in the third and fourth year post-implantation, even when the preceding follow-up has been uneventful. Long-term follow-up and explantation have a low risk. Our results affirm the safety and efficacy over the device's lifetime in clinical practice.
Abstract
BACKGROUND: Implantable cardiac monitors (ICMs) provide long-term monitoring for cardiac arrhythmias. This analysis summarizes late diagnoses, patient management and complications until 5 years after implantation. METHODS: The BIO|STREAM-ICM study is an ongoing, prospective registry capturing the real-world application of ICMs at 38 sites across 9 countries. Patients with any ICM indication are followed until device information is no longer clinically utilized. All arrhythmia diagnoses were assessed for relevance to the device indication. RESULTS: Of 1249 patients included in the present analysis, most received an ICM after syncope (56%) or cryptogenic stroke (30%). Follow-up extended to 5 years, 34% of patients had at least 3 years of monitoring. Kaplan-Meier estimates of the cumulative incidence of indication-related diagnosis were 31%, 36%, and 39% for syncope, and 21%, 24%, and 28% for cryptogenic stroke at 2, 3, and 4 years, respectively. After diagnosis, ICMs were explanted in 46% of cases, continued for monitoring of therapy efficacy in 41%, and inactivated but left in situ in 12%. Explantations needed a median duration of 10 min and were characterized as easy or very easy in 86% of cases. Six device related adverse events occurred later than 180 days after insertion, and none in the context of explantations. CONCLUSION: ICMs continue to deliver clinically meaningful arrhythmia diagnoses in the third and fourth year post-implantation, even when the preceding follow-up has been uneventful. Long-term follow-up and explantation have a low risk. Our results affirm the safety and efficacy over the device's lifetime in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic Yield and Clinical Consequences of Implantable Loop Recorder Monitoring in a Real-World Tertiary Cardiovascular Center Under Restricted Reimbursement.Healthcare (Basel, Switzerland) · 2026
- Insertable Cardiac Monitoring in Pediatric Patients: A Real-World Single-Center Experience With a New-Generation Device.Pacing and clinical electrophysiology : PACE · 2026
- Time-Dependent Diagnostic Yield and Therapeutic Impact of Implantable Loop Recorders, Brugada Syndrome as the Exception.Journal of cardiovascular electrophysiology · 2026
- Immediate Ambulatory Electrocardiographic Monitoring in Syncope.The New England journal of medicine · 2026
- Insertable cardiac monitors after hf exacerbation: a target-trial emulation studyEuropean Heart Journal · 2026
- Real-world evaluation of the positive predictive value and transmission burden of a novel implantable cardiac monitor with a remote reprogramming capability: insights from a single-center experienceFrontiers in Cardiovascular Medicine · 2026