Predicting Major Adverse Events With Cardiac Resynchronization, Leadless, and Conduction System Pacemaker Implantation.
Samuel W Reinhardt, Yongfei Wang, Omar Aldaas, Maria Camila Trejo Paredes, Karl E Minges, Kimberly Marshall, Beth Denton, Sarah Zimmerman,
Section of Cardiology, Department of Medicine, University of Chicago, Chicago, Illinois, USA. · Center for Outcomes Research and Evaluation, Yale-New Haven Hospital, New Haven, Connecticut, USA.
Key points
From the paper's conclusion- We developed a risk model for CRT-P, leadless, and conduction system pacemakers with overall helpful risk prediction, although it varied by device type. Modifications to the EPDI Registry data collection form and larger numbers of procedures in the registry over time will allow for separate, device-specific risk models in the future that may offer improved performance.
Abstract
BACKGROUND: Large-scale contemporary risk prediction models for adverse events after pacemaker implantation are lacking. The National Cardiovascular Data Registry EP Device Implant Registry has collected data on pacemaker implantations including cardiac resynchronization therapy pacemakers (CRT-P), leadless pacemakers, and His/left bundle pacemakers since April 2021. OBJECTIVES: To produce a standardized risk model for in-hospital complications following CRT-P, leadless, and His/left bundle pacemaker procedures. METHODS: Data from 21,211 novel pacemaker procedures across 179 hospitals from January 2022 to June 2024 were used to develop and validate a model to predict in-hospital complications. RESULTS: The overall in-hospital complication rate was 2.00% (range 1.69%-2.23% and interquartile range 1.98%-2.01%), which varied somewhat by device type: CRT-P 1.76%, leadless pacemaker 2.51%, and His/left bundle pacemaker 1.85%, p = 0.0052. Prior MI, prior cardiac arrest, sodium >145 mEq/L, and being hospitalized for cardiac or non-cardiac reasons not related to the procedure were the most significant risk factors for complications. The model demonstrated moderate discrimination with a C-index of 0.714 for the total cohort; this varied somewhat but showed helpful discrimination for each device-type (C-index of 0.716 for CRT-P, 0.795 for leadless pacemakers, and 0.663 for His/left bundle pacemakers). CONCLUSIONS: We developed a risk model for CRT-P, leadless, and conduction system pacemakers with overall helpful risk prediction, although it varied by device type. Modifications to the EPDI Registry data collection form and larger numbers of procedures in the registry over time will allow for separate, device-specific risk models in the future that may offer improved performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pacing‐Induced Cardiomyopathy in Leadless and Transvenous Pacemakers: A Meta‐Analysis and Meta‐RegressionPacing and Clinical Electrophysiology · 2026
- Machine Learning-based Prediction of Pacing-Induced Cardiomyopathy in Patients with Atrioventricular Block Underlying Heart Failure with Mildly Reduced or Preserved Ejection FractionmedRxiv · 2026
- Leadless pacemaker in atrioventricular block patients with specific indications: a systematic review.Frontiers in cardiovascular medicine · 2026
- Adverse Event Profiles of Leadless Pacemaker Systems Reported to the FDA MAUDE Database (2021-2026).Journal of cardiovascular electrophysiology · 2026
- Evolution of Tined Leadless Pacemaker Implantation: Patient Selection, Implant Volume, Center Characteristics, and Safety Trends.Heart rhythm · 2026
- Leadless Versus Transvenous Pacing: Propensity-Matched 12-Month Outcomes.Pacing and clinical electrophysiology : PACE · 2026