Effectiveness of Tomazoni Measurement Method for Central Catheter Tip Positioning in Neonates: A Randomised Controlled Trial
Giulia Ribeiro Schettino Regne, Catharine Galvão Diniz, Denise Miyuki Kusahara, Luciano Marques dos Santos, Patrícia Kuerten Rocha, Bruna Figueiredo Manzo
Universidade Federal de Minas Gerais · Universidade Federal de São Paulo
Key points
From the paper's conclusion- The Tomazoni measurement method was associated with substantially higher rates of central PICC tip positioning and reduced need for catheter withdrawal compared with the traditional method.
Abstract
BACKGROUND: Accurate peripherally inserted central catheter (PICC) tip positioning in neonates remains challenging, with high rates of malposition reported using traditional measurement methods. AIM: To evaluate the effectiveness of the Tomazoni method for PICC positioning in neonates compared with the traditional method. STUDY DESIGN: Pragmatic, parallel-group randomised clinical trial with stratified block randomisation, conducted in a neonatal intensive care unit in Brazil between June 2024 and April 2025. RESULTS: Of 62 randomised procedures, 55 were evaluable (27 in the experimental group, 28 in the control group). Central positioning was achieved in 21 of 27 procedures (77.8%) in the experimental group versus 5 of 28 (17.9%) in the control group (p < 0.001). PICC insertion procedures assessed using the Tomazoni method were 4.36 times more likely to achieve central tip placement (RR = 4.36; 95% CI: 1.91-9.88). Catheter withdrawal was required in 3 of 27 procedures (11.1%) in the experimental group versus 16 of 28 (57.1%) in the control group (p = 0.001; RR = 0.19; 95% CI: 0.06-0.59). CONCLUSIONS: The Tomazoni measurement method was associated with substantially higher rates of central PICC tip positioning and reduced need for catheter withdrawal compared with the traditional method. RELEVANCE TO CLINICAL PRACTICE: The Tomazoni method offers a reproducible, low-cost measurement strategy that can be implemented in neonatal intensive care units to improve catheter positioning accuracy and reduce procedure-related manipulations, with potential implications for patient safety. The trial, titled 'Comparison between measurements of peripherally inserted central catheters in children and newborns', was registered in the Brazilian Clinical Trials Registry under the identifier RBR-55zwb45. TRIAL REGISTRATION: This trial is registered in the Brazilian Clinical Trials Registry (ReBEC) under the identifier RBR-55zwb45.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improving PICC Placement Using Bedside Ultrasound in a Level IV NICU: A Quality Improvement Project.Advances in neonatal care : official journal of the National Association of Neonatal Nurses · 2026
- Development of an anthropometric prediction model for neonatal PICC insertion Depth: a multicenter study.BMC pediatrics · 2026
- Effectiveness of Transillumination Device on Reducing Peripheral Intravenous Catheter Placement Complications in Pediatric Patients: A Randomized Controlled Trial.The journal of nursing research : JNR · 2026
- Caudal-Threaded Versus Direct Lumbar/Thoracic Epidural Catheters in Small-Weight Infants-A Single-Center Retrospective Observational Study.Children (Basel, Switzerland) · 2026
- Effects of two securement methods on peripherally inserted central catheter stability and skin integrity in very low birth weight infants: a retrospective study.Translational pediatrics · 2026
- Neonatal Peripheral Arterial Cannulation: An Australian and New Zealand Survey.Journal of paediatrics and child health · 2026