Improving PICC Placement Using Bedside Ultrasound in a Level IV NICU: A Quality Improvement Project.
Casey Caddell, Jessica Lewis, Tammy Rood, Jan Sherman
Author Affiliations: Sinclair School of Nursing, University of Missouri-Columbia, Columbia, Missouri (Caddell, Rood, and Sherman); Wash U./St Louis Children's, Hospital, St. Louis, Missouri (Lewis).
Key points
From the paper's conclusion- POCUS utilization increased from 7% to 27% (P = .001). POCUS-guided insertion was associated with higher rates of single radiograph confirmation (92% vs. 42%, P < .001). No difference in total radiographs was observed. Sterile procedure time increased in the later phase (P = .026). No CLABSI occurred in the POCUS group.
Abstract
BACKGROUND: Accurate peripherally inserted central catheter (PICC) tip placement in neonates is critical to prevent complications and minimize repeated radiographic exposure. Reliance on radiography may delay confirmation and increase radiation risk in this vulnerable population. PURPOSE: To evaluate the impact of a standardized point-of-care ultrasound (POCUS) protocol on PICC placement accuracy, radiographic utilization, and procedural efficiency in a Level IV neonatal intensive care unit (NICU). METHODS: A longitudinal pre-post quality improvement design compared early (March-May 2025) and later (August-October 2025) implementation phases. A consecutive sample of 145 neonates requiring PICC placement was included. The intervention incorporated real-time ultrasound guidance, bubble test confirmation of tip position, and image documentation performed by credentialed providers. Outcomes included POCUS utilization, number of radiographs, line adjustments, sterile procedure time, and central line-associated bloodstream infection (CLABSI). Data were analyzed using χ2 and independent samples t-tests (P ≤ .05). RESULTS: POCUS utilization increased from 7% to 27% (P = .001). POCUS-guided insertion was associated with higher rates of single radiograph confirmation (92% vs. 42%, P < .001). No difference in total radiographs was observed. Sterile procedure time increased in the later phase (P = .026). No CLABSI occurred in the POCUS group. IMPLICATIONS FOR PRACTICE AND RESEARCH: Implementation of a POCUS-guided PICC protocol improved confirmation efficiency and reduced reliance on multiple radiographs. Increased sterile time likely reflected early adoption and workflow integration. Findings support continued implementation with ongoing training; however, additional prospective studies with larger samples are needed before widespread adoption can be recommended.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- POCUS-guided nasojejunal tube placement reduces malposition and radiation exposure in neonates: a multicenter real-world retrospective study.Pediatric research · 2026
- The applications, complications, and management of neonatal peripherally inserted central catheters (n-PICCs): a narrative review.Frontiers in pediatrics · 2026
- Effectiveness of Tomazoni Measurement Method for Central Catheter Tip Positioning in Neonates: A Randomised Controlled TrialNursing in Critical Care · 2026
- Effectiveness of Transillumination Device on Reducing Peripheral Intravenous Catheter Placement Complications in Pediatric Patients: A Randomized Controlled Trial.The journal of nursing research : JNR · 2026
- Peripheral IV Catheter Longevity With Ultrasound Guidance in the PICU: Single-Center Retrospective Cohort, 2016-2018.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2026
- Point-of-care ultrasound in neonatal necrotizing enterocolitis: integrating clinician-performed evidence and nurse-led implementation.Frontiers in pediatrics · 2026