Key points
From the paper's conclusion- Topology optimization created a semi-rigid framework that incorporates the shock-absorbing benefits of polymers while maintaining the inherent fracture resistance of metallic alloys. Topology-optimized titanium frameworks provide a clinically viable solution for reducing prosthetic weight and minimizing reaction forces at the abutment interface, particularly in complete-arch rehabilitations.
Abstract
PURPOSE: This study aimed to investigate the mechanical behavior of titanium frameworks with triply periodic minimal surface (TPMS) lattice structures designed for additive manufacturing by topology optimization for complete arch implant-supported fixed dental prostheses. MATERIALS AND METHODS: A maxillary model supported by four implants (two posteriorly tilted and two anterior parallel) was virtually modeled using a dental computer-aided design program. Titanium frameworks for complete arch implant-supported fixed dental prostheses, which incorporated three distinct TPMS lattice structures (Schwarz, Diamond, and Lidinoid) with variable cell wall thicknesses, were designed using topology optimization software. A total of 36 optimized framework designs were analyzed by finite element analysis under vertical and oblique loading (200 N) at the canine, premolar, and molar (cantilever) regions. A solid, non-optimized titanium framework was the control group. von Mises stress (MPa), maximum displacement (µm), reaction forces (N), and weight reduction ratios (%) were analyzed. Statistical analyses were performed with ANOVA and Tukey's post hoc test (α = 0.05). RESULTS: All topology-optimized frameworks achieved >30% weight reduction, with the Diamond lattice structure demonstrating the highest reduction of 39.92 ± 2.60 (p < 0.001). Although optimized frameworks exhibited higher displacement and stress values than solid controls because of increased flexibility, the peak stress values (190-210 MPa) remained significantly below the yield strength of titanium. Optimized frameworks generated significantly lower reaction forces than solid controls under canine and premolar loading, indicating an energy-absorbing effect. CONCLUSIONS: Topology optimization created a semi-rigid framework that incorporates the shock-absorbing benefits of polymers while maintaining the inherent fracture resistance of metallic alloys. Topology-optimized titanium frameworks provide a clinically viable solution for reducing prosthetic weight and minimizing reaction forces at the abutment interface, particularly in complete-arch rehabilitations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tailored performance of additively manufactured titanium TPMS bone scaffoldBioprinting · 2025
- Lattice and Triply Periodic Minimal Surface Architectures for Dental Implants: A Scoping Review of Design, Manufacturing, and Performance.Journal of biomedical materials research. Part B, Applied biomaterials · 2026
- Manufacturable design and experimental investigation of functionally graded TPMS-based root analogue implant for dental applicationsResults in Engineering · 2026
- Finite element analysis of weight-strength trade-offs in Ti6Al4V sternal implant designMATEC Web of Conferences · 2026
- Design and Comparative Numerical Analysis of AlSi10Mg PBF-LB/M Manufactured TPMS Lattice Structures for Improved Mechanical PerformanceMaterials · 2025
- Digital Design of Kurtosis-Controlled Ti-6Al-4V Lattices for Patient-Specific Orthopedic Implants: A Computational Framework.Bioengineering (Basel, Switzerland) · 2026