Biomechanical impact of anterior cantilever length on subperiosteal implants with different materials and configurations.
Bersu Bedirhandede, Beyza Güney, Dilan Gizem Doğan, Barış Erkut Türk
Department of Prosthodontics, Faculty of Dentistry, Gazi University, Ankara, Turkey. · Department of Prosthodontics, Şehit Ömer Emiroğlu Oral and Dental Health Center, Çorum, Turkey.
Key points
From the paper's conclusion- Anterior cantilever length influences stress distribution in subperiosteal implant-supported prostheses, with stress magnitudes increasing proportionally to cantilever extension regardless of material or configuration.
Abstract
PURPOSE: The aim of this study was to evaluate the influence of anterior cantilever length on stress distribution in subperiosteal implants (SI) fabricated from titanium and 60% carbon fiber-reinforced polyetheretherketone (PEEK) with one-piece and two-piece configurations using finite element analysis. MATERIALS AND METHODS: Sixteen three-dimensional finite element models of an atrophic maxilla were constructed, incorporating one-piece and two-piece SI designs fabricated from titanium and 60% carbon fiber-reinforced PEEK with anterior cantilever lengths of 0, 2, 4, and 6 mm. All materials were assumed isotropic, homogeneous, and linearly elastic. A 100 N oblique load at 45° was applied to the palatal region of the maxillary anterior teeth in a labio-apical direction to simulate anterior functional loading. Maximum principal stress, minimum principal stress, and von Mises stress were evaluated in the supporting bone, implant body, fixation screws, and prosthetic bar. RESULTS: Maximum and minimum principal stress values in the supporting bone progressively increased with cantilever length, with minimal material-related differences. Fixation screw von Mises stress values increased with cantilever length and were consistently higher in one-piece than in two-piece designs. Prosthetic bar von Mises stress values peaked at 2 mm. Subperiosteal implant von Mises stress values increased with cantilever length and were substantially higher in two-piece designs than in one-piece designs. CONCLUSIONS: Anterior cantilever length influences stress distribution in subperiosteal implant-supported prostheses, with stress magnitudes increasing proportionally to cantilever extension regardless of material or configuration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of distal cantilever and anterior implant diameter on framework and cortical bone stress in a PEEK-based All-on-Four mandibular prosthesisFrontiers in Dental Medicine · 2026
- Effect of Connection Geometry and Cantilever Length on the Mechanical Behavior of Ti6Al4V and PEEK Bar-Supported Implant Prostheses with Angled Abutments.Journal of functional biomaterials · 2026
- Biomechanical Interaction Between Endosseous and Patient-Specific Subperiosteal Implants in Full-Arch Rehabilitation of the Atrophic Maxilla: A Finite Element Analysis.The International journal of oral & maxillofacial implants · 2026
- PEEK plates for the fixation of mandibular condylar base fractures: a finite element analysis comparison of single and double plate configurations with titanium and resorbable systems.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Clinical and Finite Element Evaluation of Fixed Implant Prosthesis Designs for the Edentulous MandibleClinical Implant Dentistry and Related Research · 2026
- Posterior Implant Tilt as an Alternative to Sinus Elevation in Full-Arch Maxillary Rehabilitation: A Comparative Finite Element Analysis.Journal of stomatology, oral and maxillofacial surgery · 2026