Transperineal Ultrasound Assessment of Fetal Head Descent and Successful Manual Rotation in Women Undergoing Labor With Neuraxial Analgesia.
Yusuke Suzuki, Hiroko Takita, Ryu Matsuoka, Shin Hashiramoto, Yuki Mukai, Takeshi Nakamura, Akihiko Sekizawa
Department of Obstetrics and Gynecology, Showa Medical University School of Medicine, Tokyo, Japan.
Key points
From the paper's conclusion- Manual rotation performed under neuraxial analgesia was associated with a high-procedural success rate. A TUS-station ≥ 14.3 mm was associated with a high likelihood of successful manual rotation and may provide complementary information when considering the procedure, although further validation is required.
Abstract
AIM: Manual rotation is commonly used to correct fetal head malrotation during labor. This study assessed the effectiveness of manual rotation under neuraxial analgesia and evaluated whether transperineal ultrasound (TUS)-derived parameters were associated with procedural success and could provide additional information when considering manual rotation. METHODS: We conducted a retrospective cohort study of 59 women with fetal rotational abnormalities during labor under neuraxial analgesia at a tertiary care center. Rotational abnormalities were defined as occiput posterior or occiput transverse positions with a midline angle (MLA) ≥ 45°, assessed 1 h after full cervical dilation. Manual rotation success was defined as correction to an MLA < 45°. Delivery, maternal, neonatal, and TUS-derived parameters were compared between successful and unsuccessful cases. RESULTS: Manual rotation was successful in 44 of 59 cases (74.5%). The vaginal delivery rate was significantly higher in the successful group than in the unsuccessful group (90.9% vs. 46.7%, p < 0.001). No significant differences were noted in maternal or neonatal outcomes. Among TUS parameters, only the TUS-station was significantly associated with procedural success. Receiver operating characteristic analysis identified a cutoff of 14.3 mm, above which the likelihood of successful rotation was 95.8%. In exploratory logistic regression models, TUS-station remained associated with successful manual rotation after adjustment for clinically relevant covariates. CONCLUSIONS: Manual rotation performed under neuraxial analgesia was associated with a high-procedural success rate. A TUS-station ≥ 14.3 mm was associated with a high likelihood of successful manual rotation and may provide complementary information when considering the procedure, although further validation is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pre-forceps intrapartum ultrasound measurements are associated with difficult forceps delivery in nulliparous womenScientific Reports · 2026
- A Mobilisation Protocol in the Management of Posterior Foetal Presentations: A Multicentre Observational Pilot Study.Healthcare (Basel, Switzerland) · 2026
- Maternal and neonatal outcomes of Kielland's rotational forceps-assisted vaginal births in a tertiary care center.AJOG global reports · 2026
- Short-term effects of myofascial release with therapist-mediated transcutaneous electrical nerve stimulation in adolescent idiopathic scoliosis: an exploratory randomized controlled trial.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2026
- Association between oxytocin discontinuation during active labor and occiput posterior rotation at birth.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2026
- Intrapartum rectovaginal distance as a predictor of obstetric anal sphincter injury: a prospective cohort study.Revista da Associacao Medica Brasileira (1992) · 2026