Pre-forceps intrapartum ultrasound measurements are associated with difficult forceps delivery in nulliparous women
Yan Pei, Yichang Tian, Yi Chen, Yue Li, Juan Yu, Jinxin Hou, Zhuan Su, Qingqing Wu,
Key points
From the paper's conclusion- We prospectively studied 120 nulliparous women with singleton term cephalic pregnancies undergoing Simpson forceps-assisted delivery.
Abstract
Forceps-assisted vaginal delivery can avert second-stage cesarean delivery, but how difficult the procedure will be is hard to anticipate from digital examination alone. We prospectively studied 120 nulliparous women with singleton term cephalic pregnancies undergoing Simpson forceps-assisted delivery. Transperineal ultrasound was performed after the decision for forceps delivery and before instrument application. Difficult forceps delivery, defined as two or more traction attempts or failed forceps delivery requiring cesarean delivery, occurred in 25 women (20.8%). A smaller angle of progression and a non-upward fetal head direction were independently associated with difficult delivery, whereas digitally assessed fetal station was not. The ultrasound model had an apparent area under the curve of 0.845 (95% CI, 0.751–0.939) and an optimism-corrected value of 0.834; adding clinical variables did not improve discrimination (ΔAUC, 0.045; P = 0.19). An exploratory two-marker stratification separated women across a risk gradient, from 5.3% with neither unfavorable marker to 70.6% with both ( P for trend < 0.001). Pre-forceps transperineal ultrasound measurements were therefore associated with procedural difficulty in this cohort. This single-center study had 25 outcome events and the risk threshold was derived from these data; external validation and evaluation of clinical impact are required before these measurements inform management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of fetal head descent and risk of complicated forceps delivery: Role of the suprapubic descent angle.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2026
- Segmentation-assisted fetal head descent measurement in intrapartum transperineal ultrasoundFrontiers in Medicine · 2026
- Midline Angle as a Predictor of Neonatal Orbital Compression During Forceps Delivery in Occiput Anterior PresentationsJournal of Obstetrics and Gynaecology Research · 2026
- Self-operated home ultrasound for pre-labor pushing training: a proof-of-concept study.BMC pregnancy and childbirth · 2026
- Ultrasound examination during labor - a prospective pilot comparative study of clinical and ultrasonographic accuracy.Ceska gynekologie · 2026
- Development and Internal Validation of a Predictive Model for Prolonged Second-Stage Labor Using First-Stage Data: A Prospective Observational Study.Journal of visualized experiments : JoVE · 2026