Evaluation of a Multipolar MEMS Based Low-Power Radiofrequency Device for Pain-Free Facial Rejuvenation: A Prospective Clinical Study.
Rongwei Mao, Shengshuo Yan, Aditi A Sharma, Tony Shum, Yang Zhang
Department of Electrical Engineering and Computer Science University of California, Irvine Irvine California USA. · Zhejiang-California International NanoSystems Institute Hangzhou China.
Key points
From the paper's conclusion- Objective This study aimed to evaluate the safety and efficacy of a novel micro‐RF device (nebulyft), utilizing a high‐density 321‐electrode MEMS array designed to deliver high precision low‐power phase‐controlled RF energy for facial wrinkle reduction and improved skin texture.
Abstract
BACKGROUND: Noninvasive radiofrequency (RF) therapy has emerged as a prominent approach for facial rejuvenation due to its ability to stimulate collagen remodeling without epidermal ablation. However, conventional RF systems often rely on high thermal output, posing risks of heat-induced dermal damage. OBJECTIVE: This study aimed to evaluate the safety and efficacy of a novel micro-RF device (nebulyft), utilizing a high-density 321-electrode MEMS array designed to deliver high precision low-power phase-controlled RF energy for facial wrinkle reduction and improved skin texture. METHODS: In this prospective, open-label clinical trial, 42 participants from California, USA (age 29-62, Fitzpatrick skin types II-IV) completed a 4-week treatment protocol using the nebulyft device. Each subject underwent one supervised clinic-based session, followed by at-home treatments (16 min per session, ≥ 5 sessions per week). Efficacy was assessed using the Fitzpatrick Wrinkle Severity Scale (FWSS) by three blinded board-certified dermatologists, and subject satisfaction was recorded via a 4-point Likert scale. RESULTS: At one-month post-treatment visit, 90.5% of participants in the primary FAS (38/42) met the ≥ 1-point FWSS responder criterion; the supportive PPS result was 92.7% (38/41), as determined by at least two blinded evaluators (FAS exact one-sided p = 0.0015 vs. the prespecified 70% performance goal). The mean subject satisfaction score was 15.76 ± 0.54 out of 16. No pain was reported by any participant during treatment sessions. No adverse events, discomfort, or device malfunctions were reported.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sequential Monopolar–bipolar Radiofrequency for Facial Rejuvenation: A Prospective, Baseline-controlled Clinical EvaluationAesthetic Surgery Journal Open Forum · 2026
- Safety and Efficacy of a Hybrid Sequential Monopolar/Bipolar Pulsed Radiofrequency Device for Facial Rejuvenation in Skin Types III and IV: A Case SeriesInternational Journal of Aesthetic Plastic Surgery · 2026
- Microfocused ultrasound for facial and neck rejuvenation: A pilot prospective observational study on efficacy and safety in patients with skin laxity.Medicine · 2026
- Patient-reported satisfaction and experience of a novel 40.68 MHz radiofrequency therapy: a retrospective real-world study.Lasers in medical science · 2026
- UniPolar Radiofrequency for Treatment of Facial Aging Signs and Skin Laxity.Journal of cosmetic dermatology · 2026
- Multimodal Facial Rejuvenation Using Integrated Radiofrequency, Microneedle Radiofrequency, and Dynamic Muscle Stimulation: A Prospective Randomized Controlled Trial.Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.] · 2026