Laser Speckle Contrast Imaging for Assessment of Cutaneous Perfusion and Treatment Response During Hyperbaric Oxygen Therapy in Chronic Wounds: A Case Series.
Stanislas Abrard, Camille Brenac, Landry Jacquet, Judith Catella, Thierry Joffre
Department of Anesthesiology and Critical Care Medicine, Hospices Civils de Lyon, Edouard Herriot Hospital, Lyon, France. · Hospices Civils de Lyon, Hôpital Croix Rousse, Service de Chirurgie Plastique, Esthétique et Réparatrice, Lyon, France.
Key points
From the paper's conclusion- This case series demonstrates the feasibility of repeated, non-invasive LSCI assessment to characterize spatial and acute changes in cutaneous microcirculatory perfusion during HBOT.
Abstract
Hyperbaric oxygen therapy (HBOT) is an adjunctive treatment for selected chronic wounds with microcirculatory impairment, but treatment response is typically assessed clinically after several weeks. This case series evaluated the feasibility and potential utility of laser speckle contrast imaging (LSCI) for monitoring cutaneous perfusion during HBOT. Six patients with chronic wounds refractory to conventional management underwent HBOT. Cutaneous perfusion was assessed using LSCI before and after HBOT sessions at three predefined regions of interest: referent healthy skin, wound margin and wound bed. Perfusion was quantified in laser speckle perfusion units (LSPUs). Baseline perfusion differed significantly among anatomical regions (Friedman test, p < 0.001). Median perfusion was highest at the wound margin (109 [70-172] LSPU), compared with the wound bed (58 [32-92] LSPU; p = 0.001) and referent healthy skin (45 [36-61] LSPU; p < 0.001). Across monitored HBOT sessions, perfusion increased significantly after treatment in referent skin (+11 [-2 to +18] LSPU; p = 0.022), at the wound margin (+30 [-2 to +64] LSPU; p = 0.005) and in the wound bed (+10 [+1 to +32] LSPU; p = 0.010). Pre-HBOT wound-bed perfusion tended to decrease over the treatment course in most patients, although substantial inter-individual variability was observed. This case series demonstrates the feasibility of repeated, non-invasive LSCI assessment to characterize spatial and acute changes in cutaneous microcirculatory perfusion during HBOT. LSCI appears feasible for monitoring cutaneous perfusion during HBOT. Prospective studies with standardized assessment time points are needed to determine whether LSCI-derived perfusion trajectories or thresholds are associated with wound-healing outcomes and can inform HBOT decision-making.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability and Reproducibility of Laser Speckle Contrast Imaging for Assessment of Superficial Perfusion in Patients with High-Risk Feet: A Feasibility Study.Nursing reports (Pavia, Italy) · 2026
- The effect of foot temperature on laser speckle contrast imaging (LSCI) and transcutaneous oxygen pressure (TcPO2) measurements.Microvascular research · 2026
- Immediate changes of microperfusion during angioplasty of the lower limb arteriesScientific Reports · 2026
- Large area non-contact optical imaging of tissue perfusion to assess the effectiveness of percutaneous transluminal angioplasty in Asian subjects with peripheral arterial disease.Biomedical optics express · 2026
- A Multimodal Hyperspectral and Laser Speckle Imaging Platform for Simultaneous Monitoring of Spinal Cord Oxygenation, Perfusion and MetabolismarXiv · 2026
- Validation of video-rate laparoscopic multispectral imaging systems for quantitative bowel perfusion assessment using a hyperspectral reference in a porcine modelScientific Reports · 2026