Validation of video-rate laparoscopic multispectral imaging systems for quantitative bowel perfusion assessment using a hyperspectral reference in a porcine model
Denis Gholami Bajestani, Peggy Stock, Sandra Nickel, Annekatrin Pfahl, Hannes Köhler, Haukur Lindberg Sigmarsson, Johannes Kauffold, Andreas Melzer,
Key points
From the paper's conclusion- These findings show strong associations between calibrated video-rate laparoscopic multispectral imaging and hyperspectral reference imaging across perfusion states.
Abstract
Quantitative assessment of bowel perfusion remains challenging during minimally invasive surgery. This study investigated whether video-rate laparoscopic multispectral imaging can provide contrast-agent-free perfusion assessment under intra-abdominal conditions. Ten pigs were examined in vivo. Regions of the small bowel were imaged during baseline perfusion, partial vascular occlusion, and complete ischemia. Matched measurements were acquired using two prototype laparoscopic multispectral imaging systems and the approved TIVITA Mini hyperspectral imaging system as reference. The first system was evaluated in six animals and the second in four. Multispectral imaging-derived perfusion parameters from ten consecutive frames per region of interest were compared with hyperspectral near-infrared perfusion index values using linear regression, Pearson correlation, and leave-one-pig-out cross-validation. Overall, 1329 matched multispectral–hyperspectral measurements were analysed, comprising 772 from the first system and 557 from the second. System-specific correlations between multispectral imaging-derived perfusion parameters and hyperspectral reference values were strong for both systems (r = 0.915 and r = 0.840, both p < 0.001). Leave-one-pig-out validation yielded coefficients of determination of 0.812 and 0.664 and root mean square errors of 0.058 and 0.067 for the first and second systems, respectively. These findings show strong associations between calibrated video-rate laparoscopic multispectral imaging and hyperspectral reference imaging across perfusion states.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fast continuous tissue oxygenation visualization for colorectal surgery using hyperspectral light-field imagingCurrent Directions in Biomedical Engineering · 2026
- Multimodal Wearable Sensor System for Continuous Peripheral Circulation Monitoring in Postoperative Flap Care.Advanced healthcare materials · 2026
- Reliability and Reproducibility of Laser Speckle Contrast Imaging for Assessment of Superficial Perfusion in Patients with High-Risk Feet: A Feasibility Study.Nursing reports (Pavia, Italy) · 2026
- A Multimodal Hyperspectral and Laser Speckle Imaging Platform for Simultaneous Monitoring of Spinal Cord Oxygenation, Perfusion and MetabolismarXiv · 2026
- Laser Speckle Contrast Imaging for Assessment of Cutaneous Perfusion and Treatment Response During Hyperbaric Oxygen Therapy in Chronic Wounds: A Case Series.International wound journal · 2026
- In Vivo Monitoring of Pressure Ulcer Model Development and Recoverability Under Multimodal Parameters Within a Unified Field of View.Journal of biophotonics · 2026