15O-water PET-detected myocardial ischaemia and CT-derived FFR: Predicting the functional significance of anatomical stenosis.

Vornanen J, Okkonen M, Ronkainen A-P, Laitinen Tm, Laitinen Tp, Hedman M

Clinical Imaging Center, Kuopio University Hospital, Kuopio, Finland. · Heart Center, Oulu University Hospital, Oulu, Finland.

Observational · n=193

Key points

From the paper's conclusion
  • In an unselected clinical population referred for PET perfusion imaging after CCTA, CT-FFR did not significantly improve diagnostic performance compared with CCTA alone. However, in patients with high-quality CCTA and obstructive coronary stenoses, CT-FFR demonstrated good accuracy for identifying functionally significant disease, supporting its role as a complementary non-invasive diagnostic tool.

Abstract

AIMS: Coronary artery disease (CAD) is a major cause of morbidity and mortality worldwide. While coronary computed tomography angiography (CCTA) provides anatomical assessment of coronary stenoses, its ability to determine their functional significance is limited. Computed tomography-derived fractional flow reserve (CT-FFR) has emerged as a non-invasive method for lesion-specific ischaemia assessment. This study evaluated the diagnostic performance of CT-FFR using 15O-water positron emission tomography (PET) myocardial perfusion imaging as the reference standard. METHODS AND RESULTS: We retrospectively reviewed 193 patients who underwent hybrid CCTA and 15O-water PET at Kuopio University Hospital between 2017 and 2022. Patients with low-to-moderate pretest probability of CAD in whom CAD could not be ruled out by CCTA were eligible. After exclusions, 165 patients were included. CT-FFR values were calculated using a research prototype algorithm and compared with PET-derived perfusion abnormalities. In the overall cohort, CT-FFR showed moderate diagnostic performance, with area under the curve (AUC) values of 0.672-0.740. In a subgroup of 83 patients with high-quality CCTA and stenosis >50%, diagnostic performance improved substantially (AUC 0.836). Using a CT-FFR threshold of 0.80, sensitivity and specificity were 85% and 87%, respectively. CONCLUSION: In an unselected clinical population referred for PET perfusion imaging after CCTA, CT-FFR did not significantly improve diagnostic performance compared with CCTA alone. However, in patients with high-quality CCTA and obstructive coronary stenoses, CT-FFR demonstrated good accuracy for identifying functionally significant disease, supporting its role as a complementary non-invasive diagnostic tool.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

15O-water PET-detected myocardial ischaemia and CT-derived FFR: Predicting the functional significance of anatomical stenosis — Science Skim