CT-derived fractional flow reserve for anatomically long-segment coronary disease: a multicentre diagnostic accuracy study.
Ziyu An, Zhao Ma, Min Zhang, Dewei Wang, Lanxin Feng, Wenxiao Xia, Jiashuo Du, Shipan Wang,
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, P.R. China. · Department of Cardiovascular Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, P.R. China.
Key points
From the paper's conclusion- CT-FFR showed high diagnostic discrimination for invasive FFR-defined ischaemia, including in anatomically long-segment disease. However, agreement limits and threshold-zone uncertainty support its use as a non-invasive physiological adjunct rather than a direct substitute for invasive pressure-wire assessment.
Abstract
OBJECTIVES: To evaluate the diagnostic performance of CT-derived fractional flow reserve (CT-FFR) for detecting haemodynamically significant coronary disease in patients with anatomically long-segment lesions. MATERIALS AND METHODS: This retrospective multicentre study included patients who underwent coronary CT angiography and invasive pressure-wire FFR within 30 days. Anatomically long-segment disease was defined as lesion length ≥ 20 mm. Invasive FFR ≤ 0.80 was the reference standard. CT-FFR was assessed at vessel and patient levels, with patient-level CT-FFR defined as the minimum value per patient and patient-level disease as any invasive FFR ≤ 0.80. Diagnostic discrimination, threshold-based classification, and Bland-Altman agreement were evaluated. RESULTS: The diagnostic cohort included 329 patients and 377 vessels; 137 patients and 144 vessels had anatomically long-segment disease. At the vessel level, CT-FFR achieved an AUC of 0.941 (95% CI: 0.917-0.966), sensitivity of 94.3%, specificity of 83.7%, and accuracy of 88.6%. In anatomically long-segment vessels, the AUC was 0.961 (95% CI: 0.922-1.000), with sensitivity of 95.7%, specificity of 92.2%, and accuracy of 94.4%. At the patient level, the overall AUC was 0.941 (95% CI: 0.915-0.967) and 0.971 (95% CI: 0.934-1.000) in anatomically long-segment disease. Mean bias was small, although limits of agreement were clinically relevant. CONCLUSION: CT-FFR showed high diagnostic discrimination for invasive FFR-defined ischaemia, including in anatomically long-segment disease. However, agreement limits and threshold-zone uncertainty support its use as a non-invasive physiological adjunct rather than a direct substitute for invasive pressure-wire assessment. KEY POINTS: Question Does machine learning-based CT-FFR maintain diagnostic performance for invasive FFR-defined ischaemia in anatomically long-segment coronary lesions? Findings CT-derived FFR showed high diagnostic discrimination overall and maintained performance in anatomically long-segment disease, although subgroup comparisons remained exploratory. Clinical relevance CT-derived FFR may provide non-invasive physiological information in anatomically long-segment coronary disease before invasive angiography, while values near the 0.80 threshold require cautious interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of CT-derived fractional flow reserve across coronary lesion morphologies: a prospective multicenter study.The international journal of cardiovascular imaging · 2026
- 15O-water PET-detected myocardial ischaemia and CT-derived FFR: Predicting the functional significance of anatomical stenosis.Clinical physiology and functional imaging · 2026
- Impact of computed tomography-derived fractional flow reserve on long-term outcomes in patients with stable coronary artery disease: A systematic review and meta-analysis.Journal of cardiovascular computed tomography · 2026
- Seven-year Prognostic Value of Coronary CT Angiography–derived Fractional Flow Reserve in Stable AnginaRadiology · 2025
- Correlation between 15O-water PET–detected myocardial ischaemia and CT-derived FFR: Predicting the functional significance of anatomical stenosisEuropean Heart Journal · 2026
- Beyond anatomy: individual physiology-enhanced approach to improve accuracy of fractional flow reserve from computed tomographyEuropean Heart Journal · 2026