Probe Accuracy and Agreement and Patient Preferences in Peri-Implant Probing Depth Assessment: A Cross-Sectional Study.
Magdalena Mayol, Kristina Bertl, Nikolaos Pandis, Andreas Stavropoulos
Periodontology, Faculty of Odontology, Malmö University, Malmö, Sweden. · Department of Periodontology, Dental Clinic, Faculty of Medicine, Sigmund Freud University Vienna, Vienna, Austria.
Key points
From the paper's conclusion- While the electronic probe was unreliable, the metal and plastic probes were relatively accurate and comparable for assessing peri-implant PD; the plastic probe caused less pain/discomfort. However, in approximately 1/5 of the measurements a ≥ 1.5 mm deviation from the correct value (cPD) may occur, and the accuracy of the metal probe appears negatively influenced by a thick peri-implant mucosal phenotype.
Abstract
OBJECTIVES: To record the accuracy and agreement of three types of probes (i.e., a common metal probe and two types of flexible probes) for peri-implant probing depth (PD) assessment, including patient-reported outcomes (PRO). METHODS: Fifty patients (85 implants) with an implant-supported restoration were included. Peri-implant PD was recorded with a metal, plastic, and electronic probe. Pain/discomfort and patient preference were registered. After removing the prosthetic restoration, the correct peri-implant PD (cPD), the mucosal height (MH), and the PD measured from the implant level (iPD) were assessed. RESULTS: Good accuracy and agreement were noted for PD measurements with the metal and plastic probe. They differed in approximately 80% of the measurements by < 1.5 mm from cPD, and on average, an underestimation of 0.5 mm occurred. The accuracy of the metal probe was negatively influenced by a thick peri-implant mucosal phenotype. A direct comparison of the metal and plastic probes showed perfect agreement in 68.7% of the cases. Patients reported significantly less pain/discomfort when the plastic probe was used compared to the metal probe. The electronic probe was unreliable and differed by ≥ 1.5 mm from cPD in 65% of the measurements. CONCLUSIONS: While the electronic probe was unreliable, the metal and plastic probes were relatively accurate and comparable for assessing peri-implant PD; the plastic probe caused less pain/discomfort. However, in approximately 1/5 of the measurements a ≥ 1.5 mm deviation from the correct value (cPD) may occur, and the accuracy of the metal probe appears negatively influenced by a thick peri-implant mucosal phenotype. TRIAL REGISTRATION: The protocol was registered at clinicaltrials.gov (NCT05332327).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic accuracy of transmucosal probe visualization for peri‐implant mucosal phenotype assessment: A cross‐sectional studyJournal of Periodontology · 2026
- Diagnostic Accuracy and Reliability of Visual Assessment of Peri- Implant Keratinized Mucosa Width and Mucosal Thickness Using Digital Images.The International journal of periodontics & restorative dentistry · 2026
- Impact of implant surface decontamination techniques on probing depth reduction in peri-implantitis: a meta-analysis of randomized controlled trialsInternational Journal of Implant Dentistry · 2026
- Preliminary Clinical Outcomes of an Alternating-Current-Assisted Implant Surface Decontamination Protocol: A Prospective Case Series with 12-Month Follow-Up.Bioengineering (Basel, Switzerland) · 2026
- Air polishing as an adjunct to or replacement for conventional instrumentation in non-surgical peri-implantitis treatment: a systematic review and meta-analysis.Journal of dentistry · 2026
- The Accuracy of Digital vs Conventional Impression among Patients Receiving Dental Implants: A Systematic Review and Meta Analysis of Clinical Studies : Short title: Digital vs Conventional Impression among Patients Receiving Dental Implants.Galen medical journal · 2026