Journal of dentistry

Air polishing as an adjunct to or replacement for conventional instrumentation in non-surgical peri-implantitis treatment: a systematic review and meta-analysis.

Porawit Kamnoedboon, Erblina Thaqi, Dusit Nantanapiboon, Murali Srinivasan

Clinic of Gerodontology and Special Care Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland; Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand. · Clinic of Gerodontology and Special Care Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.

Meta-analysis

Key points

From the paper's conclusion
  • Low to very low certainty evidence does not show a clinically meaningful PPD benefit when air polishing is added to conventional instrumentation. For its use as a replacement, the evidence is too imprecise to establish superiority, equivalence or inferiority.

Abstract

OBJECTIVES: To address the focus question: in adults with peri-implantitis, does air polishing, used as an adjunct to or a replacement for non-surgical instrumentation, improve disease resolution and probing pocket depth (PPD) compared with instrumentation alone? DATA AND SOURCES: MEDLINE (PubMed), Web of Science, Scopus, EMBASE and the Cochrane Central Register of Controlled Trials (CENTRAL) were searched from inception to 15 July 2026. METHODS: Randomized and non-randomized comparative studies were eligible if the case definition required bleeding and/or suppuration on probing and radiographic bone loss. PPD and bleeding on probing (BOP) were pooled in a random-effects model with therapeutic role as a pre-specified subgroup, using Hartung-Knapp-Sidik-Jonkman intervals and adjustment for clustering of implants within patients. Other outcomes were synthesized without meta-analysis (SWiM), and certainty was rated with GRADE. RESULTS: Fourteen studies were included, ten in the meta-analysis. At six months, the mean difference in PPD change was -0.03 mm (95% CI -0.38 to 0.31) for adjunctive and +0.04 mm (95% CI -0.52 to 0.59) for replacement use, with no subgroup difference (p = 0.78) and negligible heterogeneity (I² = 3.4%). No significant differences were found at other timepoints or for BOP. Certainty was low for adjunctive PPD change and very low for all other outcomes. CONCLUSIONS: Low to very low certainty evidence does not show a clinically meaningful PPD benefit when air polishing is added to conventional instrumentation. For its use as a replacement, the evidence is too imprecise to establish superiority, equivalence or inferiority. CLINICAL SIGNIFICANCE: Adding air polishing to non-surgical peri-implantitis therapy has not been shown to improve outcomes beyond conventional instrumentation, and evidence on its use as a replacement is inconclusive. Given the low certainty of the evidence, well-designed trials with standardized endpoints are needed before firm recommendations can be made. PROSPERO Registration: CRD42023447967.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers