Cortisol Cutoffs for Adrenal Insufficiency Using Elecsys II: A Systematic Review.
Sarah Haunton, Nicola Leppinen, Heather MacDonald, Rebecca A Tobin, Raoul Rooman, Leanne M Ward, Alexandra Ahmet, Utkarsh J Dang
Carleton University, Ottawa, Ontario, Canada. · PendoCon bv, Putte, Belgium.
Key points
From the paper's conclusion- We affirm recommendations to lower the cortisol threshold for AI when using monoclonal assays. A peak threshold of 405 nmol/L (14.7 µg/dL) is suggested for a standard-dose ACTH test on the Elecsys II assay for diagnosis of AI, acknowledging limitations related to the small number and GRADE quality of included studies.
Abstract
OBJECTIVE: Adrenal insufficiency (AI) is associated with increased risk of morbidity and mortality if improperly managed. Adrenocorticotrophin (ACTH) stimulation testing is the most widely used AI diagnostic test. Historically, a serum cortisol threshold of 500 nmol/L (18.1 µg/dL), derived using polyclonal assays, was widely used. Improved monoclonal immunoassays show reduced cross-reactivity and lower cortisol values, but no universally accepted ACTH-stimulated cortisol threshold exists. Suggestions ranging between 348 and 485 nmol/L [12.6-17.6 µg/dL] reflect methodology and cohort differences. Our objective was to systematically review the literature and recommend a revised cortisol threshold. DESIGN AND METHODS: We searched MEDLINE, Web of Science, and Google Scholar for English language studies published between January 2016 and 19 September 2023 (PROSPERO CRD42023479405). Eligible studies reported original data, used the Roche Elecsys II assay, and recommended a cortisol threshold. Quality of evidence was assessed using the GRADE framework, and risk of bias with the ArRoWS questionnaire. Multiple suggested thresholds based on ROC, sensitivity/specificity, or regression analysis were identified. RESULTS: Six studies involving 1799 samples from 430 adult and paediatric patients were included. A serum cortisol cutoff of 405 nmol/L (14.7 µg/dL) was defined based on synthesis, sensitivity analysis, and a conservative approach to reduce false‑negatives. CONCLUSIONS: We affirm recommendations to lower the cortisol threshold for AI when using monoclonal assays. A peak threshold of 405 nmol/L (14.7 µg/dL) is suggested for a standard-dose ACTH test on the Elecsys II assay for diagnosis of AI, acknowledging limitations related to the small number and GRADE quality of included studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- On the optimal time points for assessing the cortisol response in the high-dose ACTH stimulation test - a literature review.Journal of molecular endocrinology · 2026
- Adrenal insufficiency diagnosis: new approaches to indeterminate baseline cortisol.Current opinion in endocrinology, diabetes, and obesity · 2026
- Use of EQA for assessing variation in post-analytical interpretation of results using a clinical case of ?adrenal insufficiency taking into consideration variation in analytical performance of cortisol.British journal of biomedical science · 2026
- Diagnostic Accuracy Study of Morning Salivary Cortisone for Screening Adrenal Insufficiency in a Real-World Cohort.The Journal of clinical endocrinology and metabolism · 2026
- Development and validation of a sex- and age-adjusted dehydroepiandrosterone sulfate index for suspected adrenal insufficiency.European journal of endocrinology · 2026
- Plasma cortisol cut-off concentrations using the dexamethasone suppression test in patients with adrenal incidentalomas.Frontiers in endocrinology · 2026